SA-12-023 -- (RP-1397) Field Measurements of Thermal Conditions During Surgical Procedures for the Development of CFD Boundary Conditions PDF

SA-12-023 -- (RP-1397) Field Measurements of Thermal Conditions During Surgical Procedures for the Development of CFD Boundary Conditions PDF

Name:
SA-12-023 -- (RP-1397) Field Measurements of Thermal Conditions During Surgical Procedures for the Development of CFD Boundary Conditions PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
The hospital operating room (OR) thermal environmentwas investigated via field measurements that were conductedin four similar operating rooms at Denver Health MedicalCenter to determine appropriate boundary conditions forcomputational fluid dynamics (CFD) models. The primarymeasurements used infrared thermography to quantify thesurface temperatures found inside the OR. Comparisons weremade to literature to determine realistic approximations formodels of blockages and heat sources that can be used to accuratelymodel the indoor environment in CFD. Additionally, thesurface temperature of the surgical site of the patient wasmeasured to evaluate the possibility of a thermal plume fromthe surgical site. A mean surgical site temperature of 25.6°C[78.1°F] was measured, which was approximately 2.1°C[3.8°F] cooler than the surrounding skin temperature. Additionalrelevant observations of the OR environment arediscussed in order to improve the engineering knowledge ofhow these environments are used by medical personnel. Occupantheat gain was estimated at 54.3 W for an anesthetizedpatient to 102.9 W for a circulating nurse based on a combinationof field measurements and surgical personnel thermalparameters from literature. The total cooling load in a generalOR is approximately 2539 W with lighting providing 50% ofthe heat gain. The supply air T for a generic operating roomis approximately 3°C based on ASHRAE Standard 170-2008air flow requirements.
File Size : 1 file , 3.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-SA-12-023
Published : 2012

History


Related products


Best-Selling Products

ISO/IEC/IEEE 12207-2:2020
Published Date: 08/01/2020
Systems and software engineering - Software life cycle processes - Part 2: Relation and mapping between ISO/IEC/IEEE 12207:2017 and ISO/IEC 12207:2008
$83.4
ISO/IEC/IEEE 14764:2022
Published Date: 08/01/2022
Software engineering - Software life cycle processes - Maintenance
$66.9
ISO/IEC/IEEE 15026-1:2019
Published Date: 08/01/2019
Systems and software engineering - Systems and software assurance - Part 1: Concepts and vocabulary
$58.2
ISO/IEC/IEEE 15026-2:2022
Published Date: 10/31/2022
Systems and software engineering - Systems and software assurance - Part 2: Assurance case
$49.8
ISO/IEC/IEEE 15026-3:2023
Published Date: 11/01/2023
Systems and software engineering - Systems and software assurance - Part 3: System integrity levels
$49.8
ISO/IEC/IEEE 15026-4:2021
Published Date: 08/01/2021
Systems and software engineering - Systems and software assurance - Part 4: Assurance in the life cycle
$66.9