SE-14-028 -- Analyzing the Effects of Airflow Disturbances on Measurement and Control Equipment Positioned Downstream and Close to an Air Duct Elbow-For the Purpose of Optimizing System Performance Using a CFD. PDF

SE-14-028 -- Analyzing the Effects of Airflow Disturbances on Measurement and Control Equipment Positioned Downstream and Close to an Air Duct Elbow-For the Purpose of Optimizing System Performance Using a CFD. PDF

Name:
SE-14-028 -- Analyzing the Effects of Airflow Disturbances on Measurement and Control Equipment Positioned Downstream and Close to an Air Duct Elbow-For the Purpose of Optimizing System Performance Using a CFD. PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This analysis covers the effect of airflow disturbances on measurement and control equipment positioned downstream of an air duct elbow fitting in an HVAC system. The computational fluid dynamics (CFD) research separates measurement and control equipment into what can be installed within the disturbed airflow region and what can be installed downstream but away from the disturbed airflow region; ultimately, improving the overall system performance and saving energy. Methodology: a CFD software was used to model and investigate the airflow streamlines downstreamandthe air duct elbow fitting. The aim being to investigate the optimal positioning of typical heating, ventilating, and air-conditioning (HVAC) instrumentation and control devices downstream of an air duct elbow fitting.

Typical in buildingsHVACair duct velocities were considered. Results: generated by the CFD software were tabulated and supported by CFD graphical plots. Discussions were included covering typical HVAC air duct instrumentation and control devices.

Conclusion:theCFDanalysisshowedhowtheperformance of typical instrumentation and control devices can be optimized by considering airflow velocity stream lines and pressure stream lines developed downstream of an air duct elbow fitting.


File Size : 1 file , 2.9 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-SE-14-028
Published : 2014

History


Related products


Best-Selling Products

UNE-ISO/TS 10004:2010 EX
Published Date: 09/29/2010
Quality management. Customer satisfaction. Guidelines for monitoring and measuring
UNE-ISO/TS 14167:2007 EX
Published Date: 12/19/2007
Gas analysis -- General quality assurance aspects in the use of calibration gas mixtures - Guidelines (ISO/TS 14167:2003)
UNE-ISO/TS 14256-1:2007 EX
Published Date: 09/05/2007
Soil quality -- Determination of nitrate, nitrite and ammonium in field-moist soils by extraction with potassium chloride solution -- Part 1: Manual method (ISO/TS 14256-1:2003)
UNE-ISO/TS 16949:2002
Published Date: 09/30/2002
Quality management systems. Particular requirements for the application of ISO 9001:2000 for automotive production and relevant service part organizations.
UNE-ISO/TS 16949:2004 ERRATUM
Published Date: 05/14/2004
Quality management systems. Particular requirements for the application of ISO 9001:2000 for automotive production and relevant service part organizations
UNE-ISO/TS 16949:2009
Published Date: 12/16/2009
Quality management systems. Particular requirements for the application of ISO 9001:2008 for automotive production and relevant service part organizations.