SE-14-C028 -- Multizone Particulate, Formaldehyde and VOC Measurements in Two Lab Houses Under Operation of Different Whole-Building Ventilation Systems PDF

SE-14-C028 -- Multizone Particulate, Formaldehyde and VOC Measurements in Two Lab Houses Under Operation of Different Whole-Building Ventilation Systems PDF

Name:
SE-14-C028 -- Multizone Particulate, Formaldehyde and VOC Measurements in Two Lab Houses Under Operation of Different Whole-Building Ventilation Systems PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This study focused on the in-situ impacts of various whole-building dilution ventilation systems, including the impacts of differing sources of outside air and the levels of particle, formaldehyde, and other volatile organic compound (VOC) contaminants in two interior zones. The project involved testing two single-family homes in Tyler, TX that were constructed as lab homes at the University of Texas at Tyler. Exhaust ventilation testing showed higher concentrations of particulates, formaldehyde and Top 20 VOCs compared to testing under the supply and balanced ventilation systems. The central-fan-integrated supply (CFIS) ventilation system showed an 85% and 73% reduction in 0.3 to 2.0 micron particles for House 1 and House 2, respectively. This was attributable to ventilation air filtration and recirculation air filtration by operation of the central air distribution system. The CFIS and Energy Recovery Ventilator (ERV) systems showed a significant reduction in formaldehyde concentration over the Baseline, and a large 60-70% reduction in formaldehyde concentration over Exhaust. Total VOC (TVOC) measurements showed that the CFIS and ERV ventilation systems reduced TVOC by 47% and 57%, respectively, compared to the Exhaust system as averaged between the two houses. Compared to the Baseline tests, in which no ventilation was operated, the Exhaust system increased TVOC by 37% in the House 1 Main zone, and increased TVOC by 18% in the House 2 Master zone. These particulate and TVOC results highlight that the unknown source of outside air and air entry path for the Exhaust ventilation system can cause indoor air to be more contaminated depending on what contaminants are picked up as the air comes through the building enclosure. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering that air.


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-SE-14-C028
Published : 2014

History


Related products


Best-Selling Products

IEEE/MPAI 3307-2024
Published Date: 07/12/2024
IEEE Standard Adoption of Moving Picture, Audio and Data Coding by Artificial Intelligence (MPAI) Technical Specification Connected Autonomous Vehicle-Architecture (MPAI-CAV) V1
$21.6
IEEE/MPAI 3301-2024
Published Date: 11/14/2024
IEEE Standard Adoption of Moving Picture, Audio and Data Coding by Artificial Intelligence (MPAI) Technical Specification Artificial Intelligence Framework (AIF)--Version 2
$25.8
IEEE/MPAI P3302
Published Date:
IEEE/MPAI Draft Standard for Adoption of Moving Picture, Audio and Data Coding by Artificial Intelligence (MPAI) Technical Specification - Context-based Audio Enhancement (MPAI-CAE) V2.1
$26.7
IEEE/MPAI P3305
Published Date: 12/25/2024
IEEE Approved Draft Standard for Adoption of Moving Picture, Audio and Data Coding by Artificial Intelligence (MPAI) Technical Specification MPAI Metaverse Model (MMM) Architecture Version 1
$31.8
IEEE/MPAI P3306
Published Date: 12/25/2024
IEEE Approved Draft Standard for Adoption of Moving Picture, Audio and Data Coding by Artificial Intelligence (MPAI) Technical Specification Portable Avatar Format (PAF) Version 1
$22.2