SE-99-11-5 -- Simplified Tools for Evaluating Domestic Ventilation Systems PDF

SE-99-11-5 -- Simplified Tools for Evaluating Domestic Ventilation Systems PDF

Name:
SE-99-11-5 -- Simplified Tools for Evaluating Domestic Ventilation Systems PDF

Published Date:
1999

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Within an International Energy Agency (IEA) project, Annex 27, experts from 8 countries (Canada, France, Italy, Japan, The Netherlands, Sweden, UK, and USA) have developed simplified tools for evaluating domestic ventilation systems during the heating season. Tools for building and user aspects, thermal comfort, noise, energy, life cycle cost, reliability and indoor air quality (IAQ) have been devised. The results can be used both for dwellings at the design stage and after construction. The tools lead to immediate answers and indications about the consequences of different choices that may arise during discussion with clients. This paper presents an introduction to these tools. Examples applications of the indoor air quality and energy simplified tools are also provided.

The IAQ tool accounts for constant emission sources, CO 2 , cooking products, tobacco smoke, condensation risks, humidity levels (i.e., for judging the risk for mould and house dust mites), and pressure difference (for identifying the risk for radon or land fill spillage entering the dwelling or problems with indoor combustion appliances). An elaborated set of design parameters were worked out that resulted in about 17000 combinations. By using multi-variate analysis it was possible to reduce this to 174 combinations for IAQ. In addition, a sensitivity analysis was made using 990 combinations. The results from all the runs were used to develop a simplified tool, as well as quantifying equations relying on the design parameters. A computerized energy tool has also been developed within this project, which takes into account air tightness, climate, window airing pattern, outdoor air flow rate and heat exchange efficiency.

Units: SI


File Size : 1 file , 2.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-7449
Published : 1999

History


Related products


Best-Selling Products

NS-EN ISO/IEEE 11073-10201:2020
Published Date: 07/02/2020
Health informatics — Device interoperability — Part 10201: Point-of-care medical device communication — Domain information model (ISO/IEEE 11073-10201:2020)
NS-EN ISO/IEEE 11073-10404:2022
Published Date: 01/05/2023
Health informatics — Device interoperability — Part 10404: Personal health device communication — Device specialization — Pulse oximeter (ISO/IEEE 11073-10404:2022)
NS-EN ISO/IEEE 11073-10408:2022
Published Date: 01/05/2023
Health informatics — Device interoperability — Part 10408: Personal health device communication — Device specialization — Thermometer (ISO/IEEE 11073-10408:2022)
NS-EN ISO/IEEE 11073-10415:2022
Published Date: 01/05/2023
Health informatics — Device interoperability — Part 10415: Personal health device communication — Device specialization — Weighing scale (ISO/IEEE 11073-10415:2022)
NS-EN ISO/IEEE 11073-10419:2023
Published Date: 09/11/2023
Health informatics - Personal health device communication - Part 10419: Device specialization - Insulin pump (ISO/IEEE 11073-10419:2019)
NS-EN ISO/IEEE 11073-40101:2022
Published Date: 05/05/2022
Health informatics - Device interoperability - Part 40101: Foundational - Cybersecurity - Processes for vulnerability assessment (ISO/IEEE 11073-40101:2022)