SF-98-07-4 -- Acceptable Temperature Ranges in Naturally Ventilated and Air-Conditioned Offices PDF

SF-98-07-4 -- Acceptable Temperature Ranges in Naturally Ventilated and Air-Conditioned Offices PDF

Name:
SF-98-07-4 -- Acceptable Temperature Ranges in Naturally Ventilated and Air-Conditioned Offices PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
sf-98-07-4-acceptable-temperature-ranges-in-naturally-ventilated-and-air-conditioned-offices_1711449

Choose Document Language:
4.80 €
Need Help?

The thermal environment in eight naturally ventilated and eight air-conditioned offices, located throughout England, was continuously monitored for one week in winter and one week in the following summer. The occupants assessed their thermal sensation (TS) every half-day on the ASHRAE seven-point scale. In total, 1,692 occupants made 11,450 votes in winter and 1,363 people made 9,505 votes in summer. Weighted regression analysis was used to compute the neutral temperature and acceptable temperature range relating to 3.5 £ TS £ 4.5. The overall comfort range in naturally ventilated offices in winter and summer, 4.9°C and 3.9°C (8.8°F and 7.0°F), respectively, was wider than that found in air-conditioned offices, 2.6°C and 2.4°C (4.7°F and 4.3°F), respectively. The neutral temperature in naturally ventilated offices was 0.7°C (1.3°F) lower in winter and 2.1°C (3.8°F) lower in summer than in air-conditioned offices. However, there was only a marginal difference in clothing insulation and activity levels between the two types of offices. The lower neutral temperature in naturally ventilated offices in summer may partly be due to an overestimation of warmth due to conditions typically being warmer than the previous day. Discrepancies of up to 3.0°C (5.4°F) were found between the observed neutral temperatures and those predicted by ISO 7730 for naturally ventilated offices in summer. In contrast, for the air-conditioned offices in winter and summer and naturally ventilated offices in winter, the predicted neutral temperatures were much closer to those reported, with a maximum difference of only 0.6°C (1.1°F). In winter, the percentage of occupants satisfied with the temperature in the naturally ventilated buildings (76%) was higher than in the air-conditioned offices (70%), whereas in summer, there was less satisfaction in the naturally ventilated offices (69%) than in the air-conditioned offices (73%). The occupants were less dissatisfied in the naturally ventilated buildings in winter than in summer, whereas there was only a marginal difference in dissatisfaction between seasons in the air-conditioned offices.

Units: Dual


File Size : 1 file , 200 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-7862
Published : 1998

History


Related products


Best-Selling Products

NS-ISO/IEC/IEEE 12207:2017
Published Date: 10/01/2018
Systems and software engineering — Software life cycle processes
NS-ISO/IEC/IEEE 15026-4:2021
Published Date: 06/22/2021
Systems and software engineering - Systems and software assurance - Part 4: Assurance in the life cycle
NS-ISO/IEC/IEEE 15288:2015
Published Date: 11/01/2018
Systems and software engineering — System life cycle processes
NS-ISO/IEC/IEEE 15288:2023
Published Date: 05/30/2023
Systems and software engineering — System life cycle processes
NS-ISO/IEC/IEEE 16085:2021
Published Date: 02/05/2021
Systems and software engineering — Life cycle processes — Risk management
NS-ISO/IEC/IEEE 16326:2009
Published Date: 11/01/2018
Systems and software engineering - Life cycle processes - Project management