This paper focuses on the use of performance metrics for analyzing air-management systems in data centers. Such systems are important for adequately cooling the electronic equipment and controlling the associated energy costs. Computational Fluid Dynamics (CFD) modeling has the capacity to help understand how a cooling solution will perform prior to being built. However, modeling also has the capacity to generate an unwieldy amount of data. The crux of the matter is to know what to look for and then objectively characterize and report the performance.

Performance metrics provide a great opportunity for the data center industry at large. They could form the foundation for a standardized way of specifying and reporting various cooling solutions. This paper specifically demonstrates the use of two metrics: The Rack Cooling Index (RCI) is a measure of how well the system cools the electronics within the manufacturers’ specifications, and the Return Temperature Index (RTI) is a measure of the energy performance of the air-management system. Combined, they provide an opportunity to judge the performance of the air-management system in an objective way subsequent to comprehensive CFD modeling.

A real-world example is given for demonstrating the use of these metrics to design a high-density data center. The analysis was designed to answer whether a fairly conventional raised-floor system could support significantly higher heat densities than was previously thought. By enclosing the cold equipment aisles, it is demonstrated that the cooling capacity can indeed be greatly increased. This should provide a welcome relief for many data centers that are currently running out of capacity due to a low raised floor.

Units: I-P

 


File Size : 1 file , 1.3 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-SL-08-018
Published : 2008

History


Related products


Best-Selling Products

ISO/FDIS 14644-12
Published Date: 07/01/2018
Cleanrooms and associated controlled environments -- Part 12: Specifications for monitoring air cleanliness by nanoscale particle concentration (Final Draft)
$19.5
ISO/FDIS 14644-15
Published Date: 08/01/2017
Assessment of suitability for use of equipment and materials by airborn chemical concentration
$46.8
ISO/FDIS 14644-16
Published Date: 03/04/2019
Cleanrooms and associated controlled environments - Part 16: Code of practice for improving energy efficiency in cleanrooms and clean air devices
ISO/FDIS 14644-17
Published Date: 2020
Cleanrooms and associated controlled environments - Part 17: Particle deposition rate applications
$19.5
ISO/FDIS 14644-18
Published Date: 2023
Cleanrooms and associated controlled environments - Part 18: Assessment of suitability of consumables
$19.5
ISO/FDIS 14644-3
Published Date: 04/26/2019
Test Methods