SL-90-07-4 -- The Underfloor Air Supply System - The European Experience PDF

SL-90-07-4 -- The Underfloor Air Supply System - The European Experience PDF

Name:
SL-90-07-4 -- The Underfloor Air Supply System - The European Experience PDF

Published Date:
1990

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Discusses the underfloor air supply system which was introduced into offices in the middle of the 1970s. Initially, floor outlets were combined with adjustable desk outlets. Now, floor outlets predominate. Per person, i.e., about 100 ft2 (10m2) of floor space, one to two floor outlets of 8 in. (200 mm) diameter or three to six floor outlets of 6 in. (150 mm) diameter are required. The supply air temperature is at least 64 deg F (18 deg C). The minimum distances between a fixed workplace and air outlet are 2.5 ft to 5 ft (0.8 to 1.5 m). The shorter distance applies for the smaller outlet, the larger for the wider air outlet. The floor outlets can be connected directly with the duct system, or the floor plenum is used as a pressurised plenum. The air pollution in the occupied zone is lower than in conventional air supply systems. The fresh air is guided more directly to the individuals. The costs of the complete installation are up to 10% less.

KEYWORDS: open plan spaces, ventilated furniture, displacement ventilation, local ventilation, underfloor, plenums, ventilation, air inlets, offices.


File Size : 1 file , 1.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-18710
Published : 1990

History


Related products


Best-Selling Products

UNE-CEN/TS 1099:2009 EX
Published Date: 06/24/2009
Plywood - Biological durability - Guidance for the assessment of plywood for use in different use classes
UNE-CEN/TS 12169:2009 EX
Published Date: 10/28/2009
Criteria for the assessment of conformity of a lot of sawn timber
UNE-CEN/TS 12200-2:2004
Published Date: 11/12/2004
Plastics rainwater piping systems for above ground external use - Unplasticized poly(vinyl chloride) (PVC-U) - Part 2: Guidance for the assessment of conformity
UNE-CEN/TS 12201-7:2007 EX
Published Date: 05/23/2007
Plastics piping systems for water supply - Polyethylene (PE) - Part 7: Guidance for the assessment of conformity
UNE-CEN/TS 12390-9:2008 EX
Published Date: 05/07/2008
Testing hardened concrete - Part 9: Freeze-thaw resistance - Scaling
UNE-CEN/TS 13001-3-1:2006 EX
Published Date: 06/14/2006
Cranes - General design - Part 3-1: Limit states and proof of competence of steel structures