TA-23-C041 – Pitfalls of Using CO2 Measurements as the Sole Indicator of IAQ and Airborne Transmission Risk PDF

TA-23-C041 – Pitfalls of Using CO2 Measurements as the Sole Indicator of IAQ and Airborne Transmission Risk PDF

Name:
TA-23-C041 – Pitfalls of Using CO2 Measurements as the Sole Indicator of IAQ and Airborne Transmission Risk PDF

Published Date:
2023

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Measurements of indoor CO2 concentration provide valuable information about the indoor environment. Steady-state readings give a high-quality estimate of the ratio between generation (from occupants) and removal (via ventilation), while timeseries transient readings can be used to estimate ventilation rates. Both values are key to monitoring whether the HVAC system is maintaining adequate IAQ, and they can be used as inputs to models that estimate the risk of airborne transmission of infectious aerosols (e.g., containing SARS-CoV-2, which is responsible for the COVID-19 pandemic). The increasing availability of CO2 sensors has led to a push to require CO2 monitoring in schools and other public places. Such monitoring would provide valuable data to assess IAQ. Unfortunately, this push is also accompanied by a desire to define fixed thresholds of CO2 concentration that separate “good” and “bad” IAQ as well as “safe” and “unsafe” conditions with respect to airborne transmission. Such approaches are misguided, as CO2 concentration by itself does not provide sufficient context to fully evaluate IAQ or transmission risk. Our purpose in this paper is to explain why CO2 concentration provides a partial but fundamentally incomplete picture of the indoor environment and to discuss the other key factors needed to perform a thorough assessment. For IAQ, we show how CO2 is a surrogate only for human-sourced pollutants, which means a space with low CO2 concentration could still have an unacceptably high concentration of building-sourced pollutants. For airborne transmission risk, we highlight the multiple removal mechanisms for infectious particles that have no effect on CO2 concentration, meaning that the inherent risk in two spaces with identical CO2 concentrations could vary by an order of magnitude or more depending on which disinfection technologies are deployed. Our overall goal is to illustrate the right way to integrate CO2 measurements into the overall management of IAQ and airborne transmission risk.


File Size : 1 file , 1.8 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-TA-23-C041
Published : 2023

History


Related products


Best-Selling Products

ESTA APPLICATION GUIDE FOR ANSI E1.3
Published Date: 01/01/2001
Entertainment Technology Lighting Control Systems 0 to 10V Analog Control Specification
100.00 15.00 you save 85.00
ESTA CAMERA CRANE OPERATOR'S HANDBOOK
Published Date: 01/01/2005
CAMERA CRANE OPERATOR'S HANDBOOK
100.00 15.00 you save 85.00
ESTA E1.11
Published Date: 01/01/2008
Entertainment Technology USITT DMX512-A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories
ESTA E1.11
Published Date: 01/01/2008
Entertainment Technology USITT DMX512-A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories
$12
ESTA E1.11
Published Date: 01/01/2004
Entertainment Technology USITT DMX512-A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories
$12
ESTA E1.11
Published Date: 01/01/2008
Entertainment Technology - USITT DMX512-A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories
$12