Temperature and Moisture Performance of Wall Assemblies with Fiberglass and Cellulose Insulation PDF

Temperature and Moisture Performance of Wall Assemblies with Fiberglass and Cellulose Insulation PDF

Name:
Temperature and Moisture Performance of Wall Assemblies with Fiberglass and Cellulose Insulation PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A three-year study in Champaign, Illinois, was designed to measure the thermal and moisture performance of various typical wall assemblies, especially OSB sheathing, under field conditions. The variables that were studied included:

  • insulation material (fiberglass and cellulose),
  • vapor barriers (none, polyethylene, and facing material),
  • encapsulation materials,
  • means of attachment of facing material, and
  • location within the wall cavity.

Measurements of temperature and moisture content, using Duff probes, were gathered at hourly intervals over three winters, and plugs made of the OSB sheathing material were regularly weighed for gravimetric moisture content measurements. The interior was maintained at constant humidity-50%-55% for one year and 40% for two subsequent years. Following the study, the walls were disassembled and inspected for sheathing condition and mold growth. Two samples with no vapor diffusion protection, one cellulose and one fiberglass, showed unacceptably high levels of mold growth. All of the samples with vapor barriers or encapsulation remained at a safe level of moisture content. Some of the samples with encapsulated and faced material showed mold growth at the tops of the cavities, particularly where cabling pierced the interior drywall. The construction and building pressure management for this study were such that the moisture performance is a consequence of the diffusion/capillary regime, not the air leakage regime. The cases that were unacceptably bad in this study were affected by diffusion and capillary moisture, not air leakage, under the interior and exterior loads imposed by the test.

AUTHOR: William B. Rose, David J. McCaa, Ph.D.
CITATION: Thermal Performance of the Exterior Envelopes of Buildings VII
KEYWORDS: December, Florida, 1998
YEAR: 1998


File Size : 1 file , 10 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8106
Published : 1998

History


Related products


Best-Selling Products

ISEA 101-1996 (R2008)
Published Date: 01/06/1997
Limited-Use and Disposable Coveralls - Size and Labeling Requirements
$3
ISEA 101-2014
Published Date: 07/08/2014
American National Standard for Limited-Use and Disposable Coveralls -- Size and Labeling Requirements
$3
ISEA 102-1990 (R2009)
Published Date: 05/25/1990
American National Standard for Gas Detector Tube Units - Short Term Type for Toxic Gases and Vapors in Working Environments
$3
ISEA 103-2010 Erratum (2011)
Published Date: 09/07/2011
Erratum to American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
Free Download
ISEA 103-2010
Published Date: 09/29/2010
American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
$15.9
ISEA 104-1998 (R2009)
Published Date: 07/13/1998
Air Sampling Devices - Diffusive Type for Toxic Gases and Vapors in Working Environments
$3