The Impact of Adjacent Zone Pressure on Whole-Suite Airtightness Tests in Multi-Unit Residential Buildings PDF

The Impact of Adjacent Zone Pressure on Whole-Suite Airtightness Tests in Multi-Unit Residential Buildings PDF

Name:
The Impact of Adjacent Zone Pressure on Whole-Suite Airtightness Tests in Multi-Unit Residential Buildings PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Single-fan blower door testing is commonly used for estimating the airtightness of multi-unit residential building (MURB) suites, but current testing procedures and standards do not take into consideration the impact that adjacent zone pressures may have on test results. In two case study buildings, standard whole-suite airtightness tests were conducted with the adjacent zone pressures in two conditions. The first condition had the adjacent zones at the same pressure as the atmospheric pressure, which was achieved by leaving the windows opened in these zones and monitoring interior pressures. The second condition allowed the adjacent zone pressures to reach a natural equilibrium with the test suite, while the windows were closed, resulting in interior pressures between atmospheric and the test suite pressure. The results of the tests showed that, in Building 1, air leakage at 50 Pascals (Q50) was changed by approximately 24% depending on the adjacent suite pressures, while the results from Building 2 showed no appreciable change in Q50. This higher percentage difference in Building 1 may be due to the higher interconnectedness between the suites, as compared to Building 2. Despite a small sample size of two suites, the effect of adjacent zone pressure appears to be highly variable and will likely change on a building-to-building basis. These tests highlight the importance of monitoring adjacent zone pressures during whole-suite airtightness tests in MURBs to ensure they are as close as possible to atmospheric pressure such that the test results can be more accurately interpreted.
File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-Bldgs19-025
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

UNE-CEN ISO/TS 11133-1:2009
Published Date: 09/16/2009
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 1: General guidelines on quality assurance for the preparation of culture media in the laboratory (ISO/TS 11133-1:2009)
UNE-CEN ISO/TS 11133-2:2006
Published Date: 05/10/2006
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 2: Practical guidelines on performance testing of culture media (ISO/TS 11133-2:2003)
UNE-CEN ISO/TS 11135-2:2009 EX
Published Date: 09/02/2009
Sterilization of health care products - Ethylene oxide - Part 2: Guidance on the application of ISO 11135-1 (ISO/TS 11135-2:2008)
UNE-CEN ISO/TS 15874-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Polypropylene (PP) - Part 7: Guidance for the assessment of conformity (ISO/TS 15874-7:2003)
UNE-CEN ISO/TS 15875-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Crosslinked polyethylene (PE-X) - Part 7: Guidance for the assessment of conformity (ISO/TS 15875-7:2003)
UNE-CEN ISO/TS 15876-7:2005
Published Date: 01/12/2005
Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 7: Guidance for the assessment of conformity (ISO/TS 15876-7:2003)