The Variation of Airtightness of Wood-Frame Houses Over an 11-Year Period PDF

The Variation of Airtightness of Wood-Frame Houses Over an 11-Year Period PDF

Name:
The Variation of Airtightness of Wood-Frame Houses Over an 11-Year Period PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper summarizes the most recent results from an ongoing, multi-year research program to monitor the long-term performance of residential air barrier systems. Airtightness tests were conducted on 17 houses, located in Winnipeg, Canada, ranging in age from 8 to 11 years, for which there was extensive historical data. Eight of the houses used polyethylene air barrier systems and nine used an early version of the airtight drywall approach (ADA). The latest tests were conducted in 1997. The current results showed that the average airtightness of the eight polyethylene houses was essentially unchanged over the monitoring period. Although three of the houses became somewhat leakier, most of the major leakage occurred at locations not associated with the polyethylene portions of the air barrier. It was concluded that no evidence was found to indicate that poly-ethylene is unsuited for use as an air barrier material in residential wood-frame construction, particularly given that the poly-ethylene used in the project houses was of a lower quality than now required by the National Building Code of Canada. The average leakage rate of the nine ADA houses was found to have degraded slightly, with six of the houses becoming somewhat less airtight. Once again though, most of the major leakage occurred at locations not directly associated with the ADA portions of the envelope. It was concluded that no evidence was found to indicate that the ADA system is unsuited for use in residential wood-frame construction.

AUTHOR: Gary Proskiw, P.Eng.
CITATION: Thermal Performance of the Exterior Envelopes of Buildings VII
KEYWORDS: December, Florida, 1998
YEAR: 1998


File Size : 1 file , 110 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8058
Published : 1998

History


Related products


Best-Selling Products

DRM ASME B31.3 & GUIDE SET
Published Date: 01/01/2000
ASME PROCESS PIPING / PROCESS PIPING: THE COMPLETE GUIDE TO ASME B31.3 SET (ASME B31.3 & ASME B31.3 GUIDE) - YOU SAVE 10% ***INCLUDES B31.3-2020 EDITION***
$160.5
DRM ASME B31.8 PIPING SET
Published Date: 01/01/2000
ASME GAS TRANSMISSION PIPING SET - INCLUDES ASME B31.8, ASME B31.8S, ASME B31.1, ASME B31.3 AND ASME B31.3 GUIDE - YOU SAVE 10%
$364.5
DRM DEEPWATER SET
Published Date: 01/01/2000
DEEPWATER SET INCLUDES THE FOLLOWING STANDARDS: API RP 14J, API RP 2A-WSD, API RP 2FPS, API RP 2RD, API RP 2SK, API RP 2SM, API RP 2T, API SPEC 17J, AWS D3.6M
$274.5
DRM DRM COMBO
Published Date: 01/01/2008
Drawing Requirements Manual (Hardcopy Bound & DVD)
$157.5
DRM DRM DVD
Published Date: 01/01/2008
Drawing Requirements Manual DVD
$104.7
DRM DRM
Published Date: 01/01/2008
DRAWING REQUIREMENTS MANUAL
$104.7