TO-98-12-5 -- The Effects of Varying Indoor Air Temperature and Heat Gain on the Measurement of Retrofit Savings PDF

TO-98-12-5 -- The Effects of Varying Indoor Air Temperature and Heat Gain on the Measurement of Retrofit Savings PDF

Name:
TO-98-12-5 -- The Effects of Varying Indoor Air Temperature and Heat Gain on the Measurement of Retrofit Savings PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Many methods of estimating energy savings from measured weather-dependent energy consumption data attempt to compensate for varying weather conditions between the pre- and post-retrofit periods by identifying an empirical model of pre-retrofit energy consumption and outdoor air temperature. Even though the pre-retrofit model may include a balance-point or change-point temperature, savings determined using this method implicitly assume that the indoor air set-point temperature and internal heat gains are the same during the pre- and post-retrofit periods. In this paper, we develop simplified expressions that suggest that estimates of retrofit savings are highly sensitive to minor changes in indoor air temperature and internal heat gains between the pre- and post-retrofit periods. This observation is confirmed in a mobile-home weatherization study where savings estimated with and without considering changing indoor air temperature varied by as much as 89%. These findings suggest that in simple buildings, the accuracy of estimated savings can be significantly improved by routinely measuring both indoor and outside air temperatures and explicitly including them in the baseline model for estimating savings.

Units: Dual


File Size : 1 file , 120 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-7729
Published : 1998

History


Related products


Best-Selling Products

PDA PTC PUPSIT 1
Published Date: 02/01/2020
Points to Consider for Risks Associated with Sterilizing Grade Filters and Sterilizing Filtration
$97.5
PDA PTC PUPSIT 2
Published Date: 03/01/2020
Points to Consider for Implementation of Pre-Use Post-Sterilization Integrity Testing (PUPSIT)
$97.5
PDA TR 13-2
Published Date: 11/01/2020
Technical Report No. 13-2 Fundamentals of an Environmental Monitoring Program Annex 1: Environmental Monitoring of Facilities Manufacturing Low Bioburden Products
$97.5
PDA TR 13
Published Date: 06/01/2014
Technical Report 13 Revised, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 13
Published Date: 04/22/2022
Technical Report 13 Revised 2022, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 14
Published Date: 09/01/2008
PDA Technical Report No. 14 (TR 14) Validation of Column-Based Chromatography Processes for the Purification of Proteins
$97.5