VA-89-06-1 -- Some Aspects of Gravity Driven Air Flow through Large Apertures in Buildings PDF

VA-89-06-1 -- Some Aspects of Gravity Driven Air Flow through Large Apertures in Buildings PDF

Name:
VA-89-06-1 -- Some Aspects of Gravity Driven Air Flow through Large Apertures in Buildings PDF

Published Date:
1989

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The authors compare the available algorithms for gravity-driven airflows through large openings with the requirements for multizone air-infiltration modeling.

It appears that two extreme situations are addressed in the literature. The first, providing a timeindependent airflow, is formulated in terms of the constant temperature difference between a zone and the outside. The other, considering adiabatic walls, provides a transient flow, with the cold outside air filling the zone space completely so that the airflow comes to a halt.

As an intermediate situation we present an algorithm that takes into account the heat transfer with the walls. The coupled equations for airflow and heat transfer are solved for the inside air temperature. The latter being lower than the wall temperature and always higher than the outside temperature, the proposed model predicts an air and heat flow rate, which is intermediate in magnitude with respect to the extreme situations addressed in the literature. For constant wall temperatures, the model predicts that the air flow rate is lower for zones with smaller heat exchanging wall surface area. Coupled to a thermal model for the wall surface temperature, the algorithm predicts the air flow to decrease with time. Experiments were performed on a full-scale test room with a window to the outside. During cold windless nights, velocity profiles were measured in the window plane, and the temperatures of the inside air and the walls were recorded with time.

Good agreement with the model is obtained, considering only the fraction of the wall surface area active in the heat transfer process, and measuring the inside air temperature in the outstreaming air. Effects which have been observed and should be included in the algorithm for detailed multizone air infiltration modeling are wind effects, the time development of temperature stratification, and the initial transient, whose time constant depends on furniture in the zone.


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-27228
Published : 1989

History


Related products


Best-Selling Products

CLSI AUTO01-A
Published Date: 12/20/2000
Laboratory Automation: Specimen Container/Specimen Carrier; Approved Standard, AUTO01AE
$54
CLSI AUTO02-A2
Published Date: 01/05/2006
Laboratory Automation: Bar Codes for Specimen Container Identification; Approved Standard, AUTO02A2E
$54
CLSI AUTO03-A2
Published Date: 09/01/2009
Laboratory Automation: Communications with Automated Clinical Laboratory Systems, Instruments, Devices, and Information Systems; Approved Standard, Second Edition, AUTO03A2
$54
CLSI AUTO04-A
Published Date: 03/20/2001
Laboratory Automation: Systems Operational Requirements, Characteristics, and Information Elements; Approved Standard, AUTO04AE
CLSI AUTO05-A
Published Date: 03/20/2001
Laboratory Automation: Electromechanical Interfaces; Approved Standard, AUTO05AE
CLSI AUTO07-A
Published Date: 06/20/2004
Laboratory Automation: Data Content for Specimen Identification; Approved Standard, AUTO07AE