Name:
VA-89-11-3 -- Thermal Resistance Measurement of Glazing System Edge-Seals and Seal Materials Using a Guarded Heater Plate Apparatus PDF
Published Date:
1989
Status:
Active
Publisher:
ASHRAE
In cold climates the increased edge-glass heat transfer at the perimeter of a sealed glazing unit creates a special problem. This is where condensed water and frost most readily occur. One mechanism contributing to edge-glass heat transfer is edge-seal conduction. Very few data are available regarding the thermal resistance of the various edge-seal configurations that are commercially available. An experimental procedure has been devised whereby the thermal resistance of an edge-seal can be directly measured using a guarded heater plate apparatus. Results are reported for nine edge-seal test samples. ln addition, results from similar tests provide measured thermal conductivities for four of the materials used in the construction of the edge-seal test samples and commercially available edge-seals.
| File Size : | 1 file , 780 KB |
| Note : | This product is unavailable in Russia, Belarus |
| Number of Pages : | 6 |
| Product Code(s) : | D-27258 |