SAE J2517_202210 PDF

SAE J2517_202210 PDF

Name:
SAE J2517_202210 PDF

Published Date:
10/07/2022

Status:
Active

Description:

Hybrid III Family Chest Potentiometer Calibration Procedure

Publisher:
SAE International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
sae-j2517_202210_2524177

Choose Document Language:
22.20 €
Need Help?
This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent nonlinearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is nonlinear.

Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/(volt/volt) or mm/(mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the nonlinearity and others did not. Of those that did correct for the nonlinearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Committee (DTEC) and led to overall variability in chest compression measurements between laboratories.

The intent of this recommended practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among eight labs for the chest pot sensitivity value. A follow-up round robin of this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The initial version of SAE J2517 released in May 2000 attempted to fix this problem by recommending a two-point calibration which was not intended to correct for the nonlinearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also did not require the measurement of a starting position of the potentiometer before each crash test, thus it did not correct for the difference in starting chest geometry between a subject dummy and its design intent. It was intended to be a simple and reproducible calibration procedure which crash test facilities could easily adopt with little or no modifications to their facilities. In practice, most laboratories did not adopt the procedure since it did not correct for the nonlinearities.

Recent attempts to reduce dummy-to-dummy and lab-to-lab variations at lower deflection levels (around 25 mm) have renewed interest in adopting a calibration procedure to correct for the nonlinearity of the measurement system. This current revision of this procedure uses a multipoint calibration with a third order regression to correct for the nonlinearities of the system with a standardized method. It requires changes in the calibration method of the transducer, the data collection procedures when used in a dummy, and the processing procedures after test data is collected. Following this standardized methodology will minimize linearity errors as well as lab-to-lab variations.
File Size : 1 file , 200 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 7
Published : 10/07/2022

History

SAE J2517_202210
Published Date: 10/07/2022
Hybrid III Family Chest Potentiometer Calibration Procedure
22.20 €
SAE J2517_201009
Published Date: 09/28/2010
Hybrid III Family Chest Potentiometer Calibration Procedure
19.80 €

Related products

SAE J2928_202405
Published Date: 05/17/2024
Brake Rotor Thermal Cracking Procedure for Vehicles Below 4 540 kg GVWR (Stabilized: May 2024)
30.30 €
SAE J277_201909
Published Date: 09/25/2019
Maintenance of Design Voltage - Snowmobile Electrical Systems
17.10 €
SAE J919_201307
Published Date: 07/24/2013
Sound Measurement - Off-Road Work Machines - Operator - Singular Type (Stabilized: Jul 2013)
29.40 €
SAE J1789_202106
Published Date: 06/10/2021
Self-Propelled Sweepers and Scrubbers Braking Performance
23.70 €

Best-Selling Products

NCRP 100
Published Date: 01/01/1989
Exposure of the U.S. Population from Diagnostic Medical Radiation
22.50 €
NCRP 101
Published Date: 01/01/1989
Exposure of the U.S. Population from Occupational Radiation
22.50 €
NCRP 102
Published Date: 01/01/1989
Medical X-Ray, Electron Beam and Gamma-Ray Protection for Energies up to 50 MeV (Equipment Design, Performance and Use)
24.90 €
NCRP 103
Published Date: 01/01/1989
Control of Radon in Houses
19.80 €
NCRP 104
Published Date: 01/01/1990
Relative Biological Effectiveness of Radiations of Different Quality
24.90 €
NCRP 105
Published Date: 01/01/1989
Radiation Protection for Medical and Allied Health Personnel
22.50 €