SN-CEN/TS 14972:2008 PDF

SN-CEN/TS 14972:2008 PDF

Name:
SN-CEN/TS 14972:2008 PDF

Published Date:
05/28/2008

Status:
Active

Description:

Fixed firefighting systems — Watermist systems — Design and installation

Publisher:
Standards Norway SN-CEN/TS Series

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
sn-cen-ts-14972-2008_2526994

Choose Document Language:
0
Need Help?
ADOPTED_FROM:CEN/TS 14972:2008 This document specifies requirements and gives information on design, installation and testing and gives criteria for the acceptance of fixed landbased watermist systems for specific hazards and provides fire test protocols for a variety of hazard groups. The requirements are not valid for watermist systems on ships, in aircraft, on vehicles and mobile fire appliances or for below ground systems in the mining industry. The requirements can be used as a guidance for other fixed firefighting systems, however, provided that any specific requirements for other firefighting supplies are taken into account. Aspects of watermist associated with explosion protection are beyond the scope of this document. As the fire test scenarios of this document apply to a group of similar applications, by analogy the successful performance of watermist systems also applies to that group, as defined in Annex A. Extrapolation is not covered. The document is not intended to be used as a universal design manual of watermist, as different systems have different characteristics and hence follow different design criteria to satisfy their duty requirements. In the absence of a generalized design method, it is the intent of this document that watermist systems are full-scale fire tested and its system component evaluations are conducted by qualified testing laboratories. The full system acceptance requires the relevant fire test report, the component test report(s) as well as manufacturer’s design, installation, operation and maintenance manual for the application. If the gas in the system is a significant factor for extinguishment/suppression, the relevant parts of EN 12094 and EN 15004-1 are applicable. Firefighting systems in accordance with EN 12845 and water spray systems are not covered.
Number of Pages : 76
Published : 05/28/2008

History

SN-CEN/TS 14972:2011
Published Date: 06/22/2011
Fixed firefighting systems — Watermist systems — Design and installation
SN-CEN/TS 14972:2008
Published Date: 05/28/2008
Fixed firefighting systems — Watermist systems — Design and installation

Related products


Best-Selling Products

VDI/VDE 2032
Published Date: 12/01/1975
Rolling and roller burnishing
VDI/VDE 2041
Published Date: 04/01/1991
Measurement of fluid flow with primary devices; orifice plates and nozzles for special applications
VDI/VDE 2173
Published Date: 09/01/2007
Fluidic characteristic quantities of control valves and their determination
VDI/VDE 2176
Published Date: 09/01/2007
Fluidic characteristic quantities of vanes and their determination
VDI/VDE 2177
Published Date: 07/01/1970
Description and inspection of position controllers with pneumatic gate
VDI/VDE 2178 - DRAFT
Published Date: 08/01/2008
Draft Document - Fluidic characteristic quantities of quarter turn valves and their determination