SN-CEN/TS 15410:2006 PDF

SN-CEN/TS 15410:2006 PDF

Name:
SN-CEN/TS 15410:2006 PDF

Published Date:
09/27/2006

Status:
Active

Description:

Solid recovered fuels — Method for the determination of the content of major elements (Al, Ca, Fe, K, Mg, Na, P, Si, Ti)

Publisher:
Standards Norway SN-CEN/TS Series

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
ADOPTED_FROM:CEN/TS 15410:2006 This Technical Specification specifies three methods of digestion for solid recovered fuels: a) microwave assisted digestion with hydrofluoric, nitric and hydrochloric acid mixture; b) hot water bath digestion of with hydrofluoric, nitric and hydrochloric acid mixture, after ashing of the SRFs sample; c) oven digestion with nitric, perchloric and hydrofluoric acid mixture. Instrumental determination of Si, Al, K, Na, Ca, Mg, Fe, P, and Ti is performed by Inductively Coupled Plasma Spectrometry with optical detection or other suitable spectroscopic techniques such as Flame Atomic Spectroscopy. The effectiveness of the digestion can be verified by qualitative X-ray fluorescence (XRF) analysis on the remaining residue. If necessary an alternative digestion method (among those proposed) needs to be used. XRF can be used for the analysis of Si, Al, K, Na, Ca, Mg, Fe, P, Ti, after ashing (550 °C) of the sample: other elements can be analysed by XRF providing that the concentration levels are above the instrumental detection limits of the XRF instrumentation and after proper preliminary testing. Method a) is recommended for general use, but the amount of the test portion can be very low in case of high concentration of organic matter. Method b) is recommended for SRFs with high organic matter concentration that can be difficult to digest with the other methods. Method c) is recommended for SRFs samples for which the other methods leave a significant insoluble residue. All the listed methods are suitable for the determination of Si, provided that closed containers are used for sample dissolution. XRF is highly recommended for Si, P and Ti analysis.
Number of Pages : 20
Published : 09/27/2006

History

SN-CEN/TS 15410:2006
Published Date: 09/27/2006
Solid recovered fuels — Method for the determination of the content of major elements (Al, Ca, Fe, K, Mg, Na, P, Si, Ti)

Related products


Best-Selling Products

VDI/VDE 2032
Published Date: 12/01/1975
Rolling and roller burnishing
VDI/VDE 2041
Published Date: 04/01/1991
Measurement of fluid flow with primary devices; orifice plates and nozzles for special applications
VDI/VDE 2173
Published Date: 09/01/2007
Fluidic characteristic quantities of control valves and their determination
VDI/VDE 2176
Published Date: 09/01/2007
Fluidic characteristic quantities of vanes and their determination
VDI/VDE 2177
Published Date: 07/01/1970
Description and inspection of position controllers with pneumatic gate
VDI/VDE 2178 - DRAFT
Published Date: 08/01/2008
Draft Document - Fluidic characteristic quantities of quarter turn valves and their determination