TAPPI TIP 0304-66 PDF

TAPPI TIP 0304-66 PDF

Name:
TAPPI TIP 0304-66 PDF

Published Date:
05/01/2002

Status:
Active

Description:

The Impact of Doublebacker Hot Plate Level on Board Quality and How to Measure It

Publisher:
Technical Association of the Pulp and Paper Industry

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
tappi-tip-0304-66_921486

Choose Document Language:
0
Need Help?
Hot plates in the doublebacker (DB) section must be maintained so that the leading edge of any plate is level with or slightly lower than the trailing edge of the preceding plate. The consequences of a leading edge plate that is higher than the previous plates trailing edge can be: Flutes crushed as the hot board runs into and rides over a high lead edge. This can negatively affect caliper and box compression. Disturbance of the DB glue line can occur, especially if the high leading edge is early in the hot plate section when the glue line is still in the early stages of bonding. This can cause weakened bond and delamination.
Number of Pages : 3
Published : 05/01/2002

History

TAPPI TIP 0304-66
Published Date: 2023
The Impact of Doublebacker Hot Plate Level on Board Quality and How to Measure It
14.70 €
TAPPI TIP 0304-66
Published Date: 2012
The Impact of Doublebacker Hot Plate Level on Board Quality and How to Measure It
14.70 €
TAPPI TIP 0304-66
Published Date: 01/01/2008
The Impact of Doublebacker Hot Plate Level on Board Quality and How to Measure It
TAPPI TIP 0304-66
Published Date: 05/01/2002
The Impact of Doublebacker Hot Plate Level on Board Quality and How to Measure It

Related products

TAPPI TIP 0304-30
Published Date: 07/30/2021
Use, Calibration and Maintenance of the Manually Operated Paper Micrometers
14.70 €
TAPPI UM 822
Published Date: 2012
Green Peel Bond Procedure at the Corrugator
14.70 €
TAPPI TIP 0304-32
Published Date: 09/01/2024
Causes and Corrections of Common Corrugator Bonding Problems
14.70 €

Best-Selling Products

STI/SPFA R972
Published Date: 12/01/2010
Recommended Practice for the Addition of Supplemental Anodes to sti-P3 USTs (R972)
9.00 €
STI/SPFA SP001
Published Date: 01/01/2018
Standard for the Inspection of Aboveground Storage Tanks
58.50 €
STI/SPFA SP001
Published Date: 09/01/2011
Standard for the Inspection of Aboveground Storage Tanks
51.00 €
STI/SPFA SP001
Published Date: 02/01/2024
Standard for the Inspection of Aboveground Storage Tanks
58.50 €