TIA ANSI/TIA-1194 PDF

TIA ANSI/TIA-1194 PDF

Name:
TIA ANSI/TIA-1194 PDF

Published Date:
11/18/2011

Status:
[ Active ]

Description:

Telecommunications User Premises Equipment Surge Resistibility of Smart Grid Equipment Connected to either DC or 120/240 V Single Phase AC and Metallic Communication Lines

Publisher:
Telecommunications Industry Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$27.9
Need Help?

This Standard applies to premises equipment that is connected to one or more metallic conductive communication line(s) and either a DC power source, or a 120/240 V single phase AC power service with the neutral grounded at the service entrance. It specifies the test procedures and resistibility requirements under which the communications ports of the equipment shall continue to demonstrate basic functionality when subjected to overvoltages and overcurrents on either the power lines or the communications line(s). Overvoltages or overcurrents covered by this Standard include surges due to lightning on or near the power lines or telecommunications line(s). This Standard covers the case where two or more services connected to the equipment have ground connections that may be separated by significant impedance.

PURPOSE

Most standards for the resistibility of equipment to electrical surges assume that a zero (or very low) impedance exists among all the grounds in the equipment, or among the connections to separate earth grounds. For equipment installed in the smart grid (or indeed, anywhere), the impedance of the ground connections may be significant. The purpose of this standard is to provide tests and performance criteria for the resistibility to lightning strikes of equipment connected to two or more services having at least one ground connection separated from the others by a significant impedance.

Examples of equipment with services having separate grounds include a smart grid power meter that is connected to the AC power at one side of a building and a communications service at the opposite side or a roof-mounted photovoltaic system with a communications link to the smart grid (see Figure 1).


ANSI : ANSI Approved
Edition : 11
File Size : 1 file , 700 KB
Number of Pages : 26
Published : 11/18/2011

History

TIA ANSI/TIA-1194
Published Date: 11/18/2011
Telecommunications User Premises Equipment Surge Resistibility of Smart Grid Equipment Connected to either DC or 120/240 V Single Phase AC and Metallic Communication Lines
$27.9
TIA ANSI/TIA-1194
Published Date: 11/18/2011
Telecommunications User Premises Equipment Surge Resistibility of Smart Grid Equipment Connected to either DC or 120/240 V Single Phase AC and Metallic Communication Lines
$27.9

Related products

TIA TIA/EIA-662
Published Date: 04/01/1998
Personal Wireless Telecommunications Standard (PWT)
$149.1
TIA ANSI/TIA-4953-B
Published Date: 01/17/2018
Telecommunications Communications Products Amplified Telephone Measurement Procedures and Performance Requirements
$42.3
TIA TIA-707.10-B-2
Published Date: 08/01/2014
Data Service Options for Spread Spectrum Systems: Radio Link Protocol Type 3
$42.3
TIA ANSI/TIA-4965
Published Date: 10/19/2012
Telecommunications Telephone Terminal Equipment Receive Volume Control Requirements for Digital and Analog Wireline Handset Terminals
$27.9

Best-Selling Products

SIA CP-01-2019
Published Date: 2019
Control Panel Standard - Features for False Alarm Reduction
$18