TIA TIA-455-171-B PDF

TIA TIA-455-171-B PDF

Name:
TIA TIA-455-171-B PDF

Published Date:
05/01/2019

Status:
[ Revised ]

Description:

FOTP-171 Attenuation by Substitution Measurement for Short Length Multimode Graded Index and Single-Mode Optical Fiber Cable Assemblies

Publisher:
Telecommunications Industry Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30
Need Help?
ALSO SEE NECA NEIS 301 * ANSI APPROVED

INTRODUCTION

Intent

These test methods describe procedures for measuring the attenuation by substitution of short length multimode graded index and single-mode optical fiber cable assemblies. The cable assemblies have a connector on only one end of the cable (pigtail) or have connectors on both ends of the cable (patch cord). The connectors on the patch cord may be identical or different from each other.

These tests are primarily used for multimode cables of 100 meters or less in length and for single-mode cables of any length. These tests primarily evaluate connector loss since the fiber loss is usually a small portion of the total loss. For those assemblies that are long enough for the fiber loss to be a significant portion of the loss, the fiber loss will have to be taken into account when specifying limits for the measured loss.

It is important to emphasize that measurement of the loss of a given cable assembly during a factory test will not necessarily be the same as a loss measurement of the same cable assembly in actual field use. The actual loss of the cable assembly depends on the properties of all of the mating components, the orientation of the components, and the launch condition of the light as it enters the connection. In a factory test only the components that are part of the cable assembly to be tested are accessible. The connector(s) that will be mated to the cable assembly in actual field use are not. Even though factory loss measurements are not necessarily the same as loss measurements in actual field use, the concatenation test is presented here as a suitable alternative which provides an estimate of average system loss performance.

NOTE: The results of this test method are not directly comparable with those of FOTP-34, which is an interconnection device insertion loss test. This FOTP tests cable assemblies and FOTP-34 tests a complete connection (splice, device, connector set, etc.) installed between two like fibers.


ANSI : ANSI Approved
Edition : B
File Size : 1 file , 3.6 MB
Number of Pages : 58
Published : 05/01/2019

History

TIA TIA-455-171-B
Published Date: 05/01/2019
FOTP-171 Attenuation by Substitution Measurement for Short Length Multimode Graded Index and Single-Mode Optical Fiber Cable Assemblies
$30

Related products

TIA TIA-526-4-A
Published Date: 11/01/1997
OFSTP-4 Optical Eye Pattern Measurement Procedure
$29.7
TIA TIA-604-5-F
Published Date: 12/15/2019
FOCIS 5 Fiber Optic Connector Intermateability Standard- Type MPO
$32.1
TIA TIA/EIA-455-173
Published Date: 09/01/1990
FOTP-173 Coating Geometry Measurement for Optical Fiber Side-View Method
$20.7

Best-Selling Products

NAGDM 105-1998
Published Date: 01/01/1998
American National Standard - Test Method for Thermal Transmittance and Air Infiltration of Garage Doors
$16.2
NAGDM 106-1988
Published Date: 01/01/1988
Proposed American National Standard - Official Color Codes for Torsion and Extension Springs
$16.2