TIA TIA-455-82-C PDF

TIA TIA-455-82-C PDF

Name:
TIA TIA-455-82-C PDF

Published Date:
04/07/2020

Status:
[ Active ]

Description:

FOTP-82 Fluid Penetration Test for Fluid-Blocked Fiber Optic Cable

Publisher:
Telecommunications Industry Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$24.3
Need Help?
ANSI APPROVAL

INTRODUCTION

Intent.

This test is intended to assure that a fluid-blocked fiber optic cable is filled and flooded (or otherwise appropriately fluidblocked with, for example, super-absorbents) sufficiently to restrict or otherwise prohibit the penetration and flow of water or other fluid within the core or along the cable sheath interfaces, or both. The test is designed primarily for testing filled fiber optic telecommunications cables intended for installations in underground ducts or directly buried, where ground water pressures are normally encountered; however, this test method can be used to assure or to evaluate fluid penetration integrity in other environments by specifying appropriate fluid(s), test length(s), pressure(s), allowable flow rate(s), etc., in the cable Detail Specification.

NOTE: Fiber optic cables, like many products, are available in a multiplicity of designs, and not all cable designs will perform equally well in this test (nor are they necessarily intended to be equal). Different cable sheath designs may provide fluid paths, to some degree, outside of the cable core, but such paths may be no problem in a particular application. Although applications for fluid-blocked cables generally require resistance to fluid penetration in both the core and in all sheath interfaces (or interstices), this may not always be the case.

It is the responsibility of the writer of the Detail Specification for the fiber optic cable product to determine if FOTP-82 should be a required test, how that test should be imposed (special sample preparation, etc.), and what the particular performance requirements should be (amount of fluid flow permitted, retest allowance, etc.).

Scope.

This procedure measures fluid penetration in cable.

Failure Modes.

Potential failure modes for this test include, but are not limited to:

a. Fluid travel through entire length of sample,

b. Other failure modes as may be stated in the Detail Specification.


Edition : C
File Size : 1 file , 620 KB
Number of Pages : 18
Published : 04/07/2020

History

TIA TIA-455-82-C
Published Date: 04/07/2020
FOTP-82 Fluid Penetration Test for Fluid-Blocked Fiber Optic Cable
$24.3
TIA TIA-455-82B
Published Date: 02/01/1992
FOTP 82-B Fluid Penetration Test for Fluid-Blocked Fiber Optic Cable
$24.3

Related products

TIA ANSI/TIA-455-243
Published Date: 01/28/2010
FOTP-243 Polarization-Mode Dispersion Measurement for Installed Single-Mode Optical Fibers by Wavelength-Scanning OTDR and States-of-Polarization Analysis
$55.2
TIA ANSI/TIA-942-A
Published Date: 03/01/2014
Telecommunications Infrastructure Standard for Data Centers
$223.8
TIA ANSI/TIA-455-87-B
Published Date: 03/01/1993
FOTP-87 Fiber Optic Cable Knot Test
$24.6

Best-Selling Products

SSINA Handbook D
Published Date: 07/01/1998
Stainless Steel Fabrication
$4.5