TIA TIA/EIA-515B000 PDF

TIA TIA/EIA-515B000 PDF

Name:
TIA TIA/EIA-515B000 PDF

Published Date:
10/01/1986

Status:
[ Active ]

Description:

Sectional Specification for Splice Closures for Pressurized Aerial, Buried, and Underground Fiber Optic Cables

Publisher:
Telecommunications Industry Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$27.9
Need Help?

Object

The object of this Specification is to prescribe preferred ratings and characteristics for pressurized aerial, buried or underground fiber optic splice closures; select from EIA-5150i300, "Generic Specification for Optical Fiber and Cable Splices," the appropriate quality assessment procedures, tests, and measuring methods; and to give general performance requirements for this type splice closure. This Sectional Specification must be used in conjunction with a fiber splice sectional to specify a complete optical cable splice. The Specification addresses those requirements necessary to provide external protection for an optical fiber splice, but does not cover the properties of a fiber-to-fiber splice.

Closure Types

This Sectional Specification identifies the characteristics of pressure-tight fiber optic cable splice closures designed for use with fiber optic cables in underground, buried, and aerial telecommunications applications. Moisture access into the cable closure will generally be excluded by means of a positive gas pressure system, normally not exceeding 70 kilopascals (10 pounds per square inch).

Closure Classifications

Splice closures are classified according to the configuration in which cables may enter the ends of the closure as follows:

Straight Splice Closure: Closures that provide openings for only one cable to enter each end of the closure.

Branch Splice Closures: Closures that provide openings for two or more cables to enter one or both ends of the closure.

Butt Splice Closures: Closures that provide openings such that two or more cables enter one end of the closure and no cable enters the other end of the closure.

 


Edition : 87
File Size : 1 file , 830 KB
Number of Pages : 26
Published : 10/01/1986

History

TIA TIA-515B000
Published Date: 10/01/1987
Sectional Specification for Splice Closures for Pressurized Aerial, Buried and Underground Fiber Optic Cables
$25.2
TIA TIA/EIA-515B000
Published Date: 10/01/1986
Sectional Specification for Splice Closures for Pressurized Aerial, Buried, and Underground Fiber Optic Cables
$27.9

Related products

TIA TIA/EIA-568-A
Published Date: 10/01/1995
Norma para Cableado de Telecomunicaciones en Edificios Comerciales
$89.4
TIA ANSI/TIA-526-28
Published Date: 08/30/2021
Adoption of IEC 61280-4-5:2020 Fibre-Optic Communication Subsystem Test Procedures- Part 4-5: Installed Cabling Plant- Attenuation Measurement of MPO Terminated Fibre-Optic Cabling Plant Using Test Equipment with MPO Interfaces
$55.2
TIA TIA-455-73
Published Date: 10/01/1997
FOTP- 73 Procedure for Assessing Temperature and Humidity Cycling Exposure Effects on Mechanical Characteristics of Optical Fibers
$24.6

Best-Selling Products

NBBI NB23-2007 Part 1
Published Date: 12/31/2007
National Board Inspection Code - NBIC, 2007 Edition - Part 1 - Installation
NBBI NB23-2007 Part 3
Published Date: 12/31/2007
National Board Inspection Code - NBIC, 2007 Edition - Part 3 - Repairs and Alterations
NBBI NB23-2007
Published Date: 12/31/2007
National Board Inspection Code - NBIC, 2007 Edition (Three Volumes)
NBBI NB23-2011 Part 2
Published Date: 2011
National Board Inspection Code - NBIC, 2011 Edition - Part 2 - Inspection
NBBI NB23-2011 Part 3
Published Date: 2011
National Board Inspection Code - NBIC, 2011 Edition - Part 3 - Repairs and Alterations
NBBI NB23-2011
Published Date: 2011
National Board Inspection Code - NBIC, 2011 Edition (Three Volumes)