Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures

UL 1066

1 Scope

1.1 These requirements cover low-voltage ac power circuit breakers as follows:

a) Stationary-mounted or drawout-mounted types,

b) 2-pole and 3-pole constructions,

c) Manually operated or power operated, and

d) With or without electromechanical or solid-state type trip device.

Section 1 effective April 13, 2012

1.2 These requirements apply to drawout-mounted type low-voltage ac integrally fused power circuit breakers, consisting of low-voltage ac power circuit breakers with integral current limiters or fuses.

1.3 These requirements apply to low-voltage ac fuse draw-outs consisting of current limiters or fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a fused circuit breaker.

1.4 These requirements apply to general purpose type low-voltage dc power circuit breakers.

1.5 These requirements cover equipment intended for use in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70.

1.6 These requirements are intended to supplement and be used in conjunction with the:

a) Standard for Low-Voltage AC Power Circuit Breakers Used In Enclosures, IEEE C37.13,

b) Standard for Low-Voltage DC Power Circuit Breakers Used In Enclosures, IEEE C37.14,

c) Standard for Metal-Enclosed Low-Voltage Power Circuit-Breaker Switchgear, IEEE C37.20.1,

d) Test Procedures for Switchgear - Low-Voltage AC Power Circuit Breakers Used In Enclosures, ANSI C37.50, and

e) Conformance Test Procedures for Switchgear - Metal-Enclosed Low-Voltage AC Power Circuit Breaker Switchgear Assemblies, ANSI C37.51.

1.7 These requirements cover equipment rated 600 V or less nominal, 635 V maximum ac and 300 V maximum dc.

1.8 This Standard does not apply to molded-case circuit breakers.

1.9 These circuit breakers are intended for installation in circuit breaker enclosures, switchboards (switchgear), panelboards, and the like. Drawout-mounted devices are intended for use with specific adapters or receiving equipment. The acceptability of the combination of a circuit breaker with respect to any overall enclosure will be determined when the complete product is considered.
Edition : 4
Published : 04/13/2012

History

UL 1066
Published Date: 08/08/2022
Power Circuit Breakers up to 1000 V AC and 1500 V DC Used in Enclosures
$150.6
UL 1066
Published Date: 04/13/2012
Low-Voltage AC and DC Power Circuit Beakers Used in Enclosures
UL 1066
Published Date: 05/30/1997
Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures

Related products


Best-Selling Products

NEN NEN 1006+A1
Published Date: 06/01/2018
Algemene voorschriften voor leidingwaterinstallaties
$15.9
NEN NEN 1010
Published Date: 01/01/2020
Elektrische installaties voor laagspanning – Nederlandse implementatie van de HD-IEC 60364-reeks
$130.8
NEN NEN 1059
Published Date: 06/01/2019
Nederlandse editie op basis van NEN-EN 12186 en NEN-EN 12279 - Gasvoorzieningsystemen - Gasdrukregel- en meetstations voor transport en distributie
$26.4
NEN NEN 11298-2
Published Date: 10/01/1995
Process measurement and control devices - General methods and procedures for evaluating performance - Part 2: Test under reference conditions
$17.1
NEN NEN 2075
Published Date: 09/01/2018
Quality measuring system and process control system for cleaning performance
$19.8
NEN NEN 2767‐1+C1
Published Date: 05/01/2019
Condition assessment built environment ‐ Part 1: Methodology
$21.3