Relocatable Power Taps
UL 1363
1 Scope

1.1 These requirements cover indoor use cord and plug connected, relocatable power taps (RPT) rated 250 V AC or less and 20 Amperes or less. RPT are for use as a movable power supply connection for cord and plug connected electrical utilization equipment in accordance with the National Electric Code, NFPA 70.

1.2 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs an electromagnetic interference filter is covered under the Standard for Electromagnetic Interference Filters, UL 1283.

1.3 A cord and plug connected product as described in 1.1 with less than three receptacle outlets that employs a surge protective device (SPD) is covered under the Standard for Surge Protective Devices, UL 1449.

1.4 A cord and plug connected product as described in 1.1 that employs ground-fault protection is covered under the requirements for portable GFCIs in the Standard for Ground-Fault Circuit Interrupters, UL 943.

1.5 This standard does not cover RPT intended for use with medical equipment.

1.6 A RPT may employ an integral cord reel for the supply cord and attachment plug. A cord reel provided with pull out receptacle outlets or cord connectors is covered under the Standard for Cord Reels, UL 355.

1.7 These requirements do not cover RPT's with work surfaces or surfaces intended to support weight loads other than as specified in 3.11 for the storage of hand-held electronic devices and charging equipment such as a cell phone, cell phone charger and the like.

1.8 These requirements cover RPT's provided with isolated secondary circuits.

1.9 These requirements cover RPT's provided with batteries located in isolated secondary circuits. See UL 1363 Supplement sb - Relocatable Power Taps Incorporating Batteries.

1.10 A product that has a battery backup feature or other uninterruptible power supply equipment located in the Primary Circuit shall comply with the applicable requirements in the Standard for Uninterruptible Power Supply Equipment, UL 1778.
Edition : 4
Published : 10/06/2014

History

UL 1363
Published Date: 07/13/2023
Relocatable Power Taps
UL 1363
Published Date: 10/06/2014
Relocatable Power Taps
UL 1363
Published Date: 05/02/2007
Relocatable Power Taps
UL 1363
Published Date: 01/01/1996
Relocatable Power Taps

Related products


Best-Selling Products

NETA ATS-2009
Published Date: 02/19/2009
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2009 Edition
$247.5
NETA ATS-2013
Published Date: 2013
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2013 Edition
$82.5
NETA ATS-2017
Published Date: 2017
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2017 Edition (Errata Included)
$87
NETA ATS-2021
Published Date: 09/18/2020
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2021 Edition
$87
NETA ECS-2020
Published Date: 2020
Standard for Electrical Commissioning Specifications for Electrical Power Equipment and Systems, 2020 Edition
$57
NETA ECS-2024
Published Date: 2024
Standard for Electrical Commissioning Specifications for Electrical Power Equipment & Systems, 2024 Edition
$62.7