Description:

Class 2 and Class 3 Transformers

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?


1.1 Transformers covered by these requirements, herein called Class 2 or Class 3 transformers, are for use with Class 2 or Class 3 circuits, respectively, in accordance with the National Electrical Code, ANSI/NFPA 70. They are intended for connection to essentially sinusoidal supply sources. Permanently connected transformers are rated 600 volts or less, and cord and plug connected transformers are rated 120 volts or less.

1.2 A Class 2 or Class 3 transformer that is inherently limited has an impedance within the transformer that limits the current output to a particular maximum value. It may or may not be provided with a thermostat or other temperature sensitive device to limit its maximum temperature.

1.3 A Class 2 or Class 3 transformer that is not inherently limited does not have an impedance to limit the maximum current output to a specified value. However, the maximum power output is limited by an overcurrent-protective device.

1.4 A Class 2 or Class 3 transformer that includes a separate current-limiting impedance, such as a resistor or a positive temperature coefficient device (PTC), is covered by these requirements.

1.5 A Class 2 transformer has a 30-volt rms maximum secondary potential under any condition of loading or open circuit.

1.6 A Class 2 or Class 3 transformer that includes a resonance regulating circuit is covered by these requirements.
Edition : 4th
Published : 01/01/1998

History

UL 5085-1
Published Date: 04/17/2006
Low Voltage Transformers - Part 1: General Requirements
$269.1
UL 1585
Published Date: 01/01/1998
Class 2 and Class 3 Transformers

Related products


Best-Selling Products

VDI/DGQ 3441
Published Date: 03/01/1977
Statistical Testing of the Operational and Positional Accuracy of Machine Tools; Basis
VDI/DGQ 3442
Published Date: 03/01/1977
Statical examination of exactly working of turing machines
VDI/DGQ 3443
Published Date: 03/01/1977
Statistical examination of exactly working of milling machines
VDI/DGQ 3444
Published Date: 09/01/1978
Statistical control of exactly working and positioning of coordinate drilling machines and machining centers
VDI/DGQ 3445 Sheet 1
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; fundamentels
VDI/DGQ 3445 Sheet 2
Published Date: 03/01/1977
Statistical examination of exactly working of grinding machines; external cylindrical grinding machines with center points; plunge-cut grinding operation