1.1 These requirements cover single and multiple optical-fiber cables for control, signaling, and communications as described in Article 770 and other applicable parts of the National Electrical Code (NEC). Cables complying with these requirements are:Type OFNP - Plenum - A nonconductive cable for use in ducts, plenums, and other spaces used for environmental air. A nonconductive cable contains no metallic members and no other electrically conductive materials.Type OFCP - Plenum - A conductive cable for use in ducts, plenums, and other spaces used for environm0ental air. A conductive cable contains non-current-carrying conductive members such as metal strength members and metallic vapor barriers.Type OFNR - Riser - A nonconductive cable for vertical use in shafts or from floor to floor.Type OFCR - Riser - A conductive cable for vertical use in shafts or from floor to floor.Type OFN and OFNG - General Purpose - Nonconductive cables for general purpose use.Type OFC and OFCG - General Purpose - Conductive cables for general purpose use.

1.2 Smoke and fire considerations are as follows for the cables covered in these requirements:
1.TYPE OFNP and OFCP CABLES - Cables that are intended for installation in accordance with Section 770-53(a) of the National Electrical Code (ANSI/NFPA 70-1999) in a duct, plenum, or other space used to transport environmental air without the cable being enclosed in a raceway in that space are tested for smoke and flame characteristics in accordance with the Standard Test for Flame-Propagation and Smoke-Density Values for Electrical and Optical-Fiber Cables Used in Spaces Transporting Environmental Air (UL 910). A cable that complies exhibits a maximum flame-propagation distance that is not greater than 5 ft, 0 inch or 152 cm, a peak optical density of smoke produced of 0.50 or less (32 percent light transmission), and an average optical density of smoke produced of 0.15 or less.
Edition : 3rd
Number of Pages : 18
Published : 07/08/2008

History

UL 1651
Published Date: 07/08/2008
Optical Fiber Cable
UL 1651
Published Date: 12/19/1997
Optical Fiber Cable

Related products

UL 130
Published Date: 07/15/2011
Electric Heating Pads
$299.4

Best-Selling Products

ICAC EP-7
Published Date: 01/01/2004
ELECTROSTATIC PRECIPITATOR GAS FLOW MODEL STUDIES
ICAC EP-8
Published Date: 11/01/1993
Structural Design Criteria for Electrostatic Precipitator Casings
ICAC F-3
Published Date: 01/01/2002
Operation and Maintenance of Fabric Collectors
ICAC WP-1
Published Date: 05/01/2009
White Paper: Selective Catalytic Reduction (SCR) Controls for NO x Emissions from Fossil Fuel-Fired Electric Power Plants