Description:

Data-Processing Cable

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?

1.1 These requirements cover electrical cables consisting of one or more current-carrying copper, aluminum, or copper-clad aluminum conductors with or without either or both grounding conductor(s), and one or more optical-fiber members, all under an overall jacket. These electrical and composite electrical/optical-fiber cables are intended for use (optical and electrical functions associated in the case of a hybrid cable) in accordance with Article 645 and other applicable parts of the National Electrical Code (NEC) under the raised floor of a computer room.Cables complying with these requirements are:
1.- Voltage Rating 600 volts, Flame Test: (b)
2.- same as Type DP-1 except Flame Test: (a)
3.- Voltage Rating: 300 volts, Flame Test: (b)
4.- same as Type DP-2 except Flame Test: (a)
5.- Voltage Rating none - for use in signaling circuits meeting the following requirements for maximum available voltage, current and power.

30 volts ac max. and/or other circuits designated60 volts dc max. DP-3 in accordance with42.4 volts peak max. the requirements in the100 VA max. Standard for Safety of8 amps max.Information TechnologyEquipment - UL 1950Flame Test: (b)
1.- same as Type DP-3 except Flame Test: (a)

1.2 Smoke and fire considerations are as follows for the cables covered in the requirements:
1.TYPE DP-1P, DP-2P and DP-3P CABLES - These cables are to be tested for smoke and flame characteristics in accordance with the Standard Test for Flame-Propagation and Smoke-Density Values for Electrical and Optical-Fiber Cables Used in Spaces Transporting Environmental Air, UL 910. A cable that complies exhibits a maximum flame-propagation distance that is not greater than 5 ft, 0 inch, or 1.52 m, a peak optical density of smoke produced of 0.5 or less (32 percent light transmission), and an average optical density of smoke produced of 0.15 or less.
Edition : 2nd
Published : 01/01/1999

History

UL 1690
Published Date: 01/01/1999
Data-Processing Cable

Related products


Best-Selling Products

CAN/CSA-ISO/TS 11137-4:21
Published Date: 05/01/2021
Sterilization of health care products - Radiation - Part 4: Guidance on process control (Adopted ISO technical specification 11137-4:2020, first edition, 2020-06)
$72
CAN/CSA-ISO/TS 11139:18
Published Date: 06/01/2018
Sterilization of health care products - Vocabulary (Adopted ISO/TS 11139:2006, second edition, 2006-01-15)
$32.7
CAN/CSA-ISO/TS 14048-03 (R2021)
Published Date: 03/14/2003
Environmental Management - Life Cycle Assessment - Data Documentation Format (Adopted ISO/TS 14048:2002, first edition, 2002-04-01)
$50.4
CAN/CSA-ISO/TS 14798-07
Published Date: 03/01/2007
Lifts (Elevators), Escalators and Moving Walks - Risk Assessment and Reduction Methodology
$51.3
CAN/CSA-ISO/TS 16058-05
Published Date: 02/01/2005
Health Informatics - Interoperability of Telelearning Systems (Adopted ISO/TS 16058:2004, first edition, 2004-07-01)
CAN/CSA-ISO/TS 16775:17
Published Date: 10/01/2017
Packaging for terminally sterilized medical devices - Guidance on the application of ISO 11607-1 and ISO 11607-2 (Adopted ISO technical specification 16775:2014, first edition, 2014-05-15)
$68.7