1 Scope

1.1 These requirements cover toxic and combustible gas and vapor detectors and sensors intended to be portable or employed in indoor or outdoor locations in accordance with the National Electrical Code, NFPA 70. A gas detector and/or sensor and/or vapor detector, as covered by these requirements, consists of an assembly of electrical components coupled with a sensing means inside a chamber, or by separate components to detect toxic and/or combustible gases or vapors. The detector includes provision for the connection to a source of power and signaling circuits.

1.2 These requirements cover the following types of detectors:

a) Detectors intended for monitoring the environment and detectors intended for open area protection and for connection to a compatible power supply or control unit for operation as part of gas detection or emergency signaling systems;

b) Detectors intended solely for control of ventilation or shut off devices such as fans or control valves;

c) Detectors intended for both the above applications;

d) Sensors and sensing circuits intended for use with or in gas detectors, alarms or gas detection circuits within fuel cell systems;

e) Portable gas detectors;

f) Multi-gas gas detectors;

g) Multi-gas sensors

1.3 These requirements also cover all remote accessories that are intended to be connected to a gas or vapor detector and/or sensor.

1.4 These requirements do not cover the following:

a) Control units to which the detectors are intended to be connected that are covered by the Standard for Control Units for Fire-Protective Signaling Systems, UL 864;

b) Control units to which the detectors are intended to be connected that are covered by the Standard for General Purpose Signaling Devices and Systems, UL 2017;

c) Self-contained single and multiple station carbon monoxide alarms or residential combustible gas detectors, not intended for connection to a system control unit, that are covered by the Standard for Single and Multiple Station Carbon Monoxide Alarms, UL 2034, or Residential Gas Detectors, UL 1484.

1.5 Users of these requirements will additionally need to ensure that influencing factors not addressed in these requirements for the end product installation, such as mechanical movement, field placement of conductive material, and product damage, will not affect the system for insulation coordination or performance operation. Examples are the deformation of the enclosure, movement of the fittings for conduit or armored cable, or the improper installation of field wiring.
Edition : 1st
Number of Pages : 144
Published : 11/05/2004

History

UL 2075
Published Date: 03/06/2013
Standard for Gas and Vapor Detectors and Sensors
UL 2075
Published Date: 11/05/2004
Standard for Gas and Vapor Detectors and Sensors

Related products


Best-Selling Products

Tracing EMFs in Building Wiring & Grounding
Published Date: 04/01/1995
$8.4