UL 2225 PDF

UL 2225 PDF

Name:
UL 2225 PDF

Published Date:
09/30/2013

Status:
Active

Description:

Cables and Cable-Fittings For Use In Hazardous (Classified) Locations

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$189.3
Need Help?
Please note: All interim revisions for this edition available at time of your purchase will be included.

Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
UL 2225
1 Scope

1.1 These requirements cover Type MC-HL metal-clad cable for use in hazardous (classified) locations, Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class I, Zone 1, Groups IIA, IIB, and IIC; and Zone 20, 21, and 22 in accordance with the National Electrical Code, NFPA 70.

1.2 These requirements cover Type ITC-HL instrumentation tray cable for use in hazardous (classified) locations, Class I, Division 1, Groups A, B, C, and D, and Class I, Zone 1, Groups IIA, IIB, and IIC; and Zone 20, 21, and 22 in accordance with the National Electrical Code, NFPA 70.

1.3 These requirements cover Type TC-ER-HL tray cable for use in hazardous (classified) locations, Class I, Zone 1, Groups IIA, IIB, and IIC in accordance with the National Electrical Code, NFPA 70.

1.4 These requirements cover explosionproof and dust-ignitionproof cable sealing fittings for use in hazardous (classified) locations, Class I, Division 1 and 2, Groups A, B, C, and D; Class II, Division 1 and 2, Groups E, F, and G in accordance with the National Electrical Code, NFPA 70.

1.5 These requirements cover explosionproof and dust-ignitionproof cable sealing fittings intended for use on mobile offshore oil rigs and drilling platforms, and other marine vessels. Investigations of these fittings include an evaluation for conformity to the installation and use provisions of Title 46 Code of Federal Regulations Sub-part 111.105 and Subpart 111.60 of the United States Coast Guard Electrical Engineering Regulations, Subchapter J (Parts 110 to 113 inclusive) as applied by the authority having jurisdiction.

1.6 These requirements cover increased safety "e" cable fittings and flameproof "d" cable sealing fittings for use in Class I, Zone 1 Groups IIA, IIB and IIC hazardous (classified) locations, in accordance with the National Electrical Code, NFPA 70.

1.7 These requirements cover increased safety "e" cable fittings and flameproof "d" cable sealing fittings for use in hazardous (classified) locations, Class I, Zone 1 for use on mobile offshore oil rigs and drilling platforms, and other marine vessels. Investigations of these fittings include an evaluation for conformity to the installation and use provisions of Title 46 Code of Federal Regulations Sub-part 111.105 and Subpart 111.60 of the United States Coast Guard Electrical Engineering Regulations, Subchapter J (Parts 110 to 113 inclusive) as applied by the authority having jurisdiction.

1.8 These requirements cover increased safety "e" cord connectors and flameproof "d" cord connectors for use only with extra-hard usage cord in hazardous (classified) locations, Class I, Zone 1 in accordance with the National Electrical Code, NFPA 70.

1.9 These requirements cover dust ignition protection by enclosure "t" and "tD" cable fittings for use in Zone 20, 21, and 22 hazardous (classified) locations in accordance with the National Electrical Code, NFPA 70.

1.10 These requirements cover dust ignition protection by enclosure "t" and "tD" extra-hard usage cord connectors for use in Zone 20, 21, and 22 in accordance with the National Electrical Code, NFPA 70.

1.11 These requirements apply to cables, cable fittings and cord connectors for hazardous locations under the following atmospheric conditions:
  • A minimum ambient temperature of minus 50°C (minus 58°F);
  • An oxygen concentration of not greater than 21 percent by volume; and
  • A nominal barometric pressure of one atmosphere.

Edition : 4
Note : This product is unavailable in Ukraine, Russia, Belarus
Published : 09/30/2013

History

UL 2225
Published Date: 09/30/2013
Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
$189.3
UL 2225
Published Date: 02/25/2011
Cables and Cable-Fittings For Use In Hazardous (Classified) Locations
UL 2225
Published Date:
Metal-Clad Cables and Cable-Sealing Fittings for Use in Hazardous (Classified) Locations

Related products


Best-Selling Products

AES 10
Published Date: 01/01/2003
AES Recommended Practice for Digital Audio Engineering Serial Multichannel Audio Digital Interface (MADI)
$12.6
AES 10
Published Date: 01/01/1991
AES Recommended Practice for Digital Audio Engineering - Serial Multichannel Audio Digital Interface (MADI)
AES 10ID
Published Date: 03/02/2005
AES information document for digital Audio Engineering - Engineering guidelines for the multichannel audio digital interface AES10 (MADI)
AES 11
Published Date: 01/01/2009
AES recommended practice for digital audio engineering - Synchronization of digital audio equipment in studio operations
$15
AES 12ID
Published Date: 01/01/2006
Information Document for digital audio measurements - Jitter performance specifications
$24.9
AES 14ID
Published Date: 01/01/2010
AES information document for interconnections - Universal jack for IEC 60603-11 and B-gauge 6,35 mm plugs
$15