UL 2459 PDF

UL 2459 PDF

Name:
UL 2459 PDF

Published Date:
08/22/2008

Status:
Active

Description:

Insulated Multi-Pole Splicing Wire Connectors

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
Insulated Multi-Pole Splicing Wire Connectors

UL 2459

1 Scope

1.1 This Standard covers insulated multi-pole mating or non-mating splicing wire connectors intended for field wiring and factory wiring for use in accordance with the Canadian Electrical Code, Part I, in Canada, and NFPA 70, National Electrical Code, in the United States.

1.2 These wire connectors are intended to facilitate the connection of devices, such as prefabricated wiring assemblies, smoke detectors, and lighting products, to the branch circuit conductors of buildings.

1.3 These wire connectors may additionally be used internal to luminaries to facilitate replacement of the ballast and may not be directly attached to the branch circuit conductors. These wire connectors are suitable for one or more conductors per contact.

1.4 These wire connectors are suitable for use with 30 to 6 AWG (0.05 to 13.3 mm2) stranded copper conductors and 30 to 10 AWG (0.05 to 5.3 mm2) solid copper conductors.

1.5 These wire connectors are suitable for currents not exceeding the ampacity of insulated conductors or as rated by the manufacturer.Note: The ampacity of insulated conductors 14 AWG (2.1 mm2) and larger is determined in accordance with the values in the "Assigned maximum ampere rating" column, under the heading "Copper", in Table 7 of CAN/CSA-C22.2 No. 65 or UL 486A-486B. In Canada, the maximum ampacity of insulated conductors 14 AWG (2.1 mm2) and smaller is determined in accordance with Table 12 of the Canadian Electrical Code, Part I.

1.6 These wire connectors are suitable for voltages not exceeding 600 V.

1.7 This Standard does not apply to

(a) splicing wire connectors intended for direct burial;

(b) insulated splicing wire connectors intended for use at voltage levels exceeding 600 V (1000 V in a sign or luminaire);

(c) terminal wire connectors;

(d) wire binding screw terminals;

(e) built-in terminal connectors on devices having integral cable clamps;

(f) flat quick-connect terminals;

(g) devices, such as wire connectors and soldering lugs, that are covered by

(i) CAN/CSA-C22.2 No. 65 or UL 486A-486B;

(ii) CAN/CSA-C22.2 No. 188 or UL 486C; or

(iii) UL 486E;

(h) devices, such as quick-connect terminals, that are covered by CSA C22.2 No. 153 or UL 310;

(i) devices covered by CSA C22.2 No. 182.3 or UL 1977; and

(j) devices, such as pin and sleeve connectors, that are covered by CSA C22.2 No. 182.1 or UL 1682.
Edition : 1st
Number of Pages : 60
Published : 08/22/2008

History


Related products

UL 61730-1
Published Date: 10/28/2022
Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction
$165.9

Best-Selling Products

SA/SNZ HB 119:2019
Published Date: 12/20/2019
Mines and quarries electrical protection
$43.362
SA/SNZ HB 146:2018
Published Date: 05/23/2018
Management of electrical cable in mines and quarries
$30.492
SA/SNZ HB 168:2017
Published Date: 09/18/2017
Document control
$30.492
SA/SNZ HB 205:2017
Published Date: 06/30/2017
Managing health-and-safety-related risk
$23.562
SA/SNZ HB 252:2014
Published Date: 04/28/2014
Communications cabling manual - Module 3: Residential communications cabling handbook
$33.264
SA/SNZ HB 331:2020 Amd 1:2020
Published Date: 10/01/2020
Overhead line design handbook
Free Download