UL 486D PDF

UL 486D PDF

Name:
UL 486D PDF

Published Date:
12/12/2005

Status:
Active

Description:

Insulated Wire Connectors for Use with Underground Connectors

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
Insulated Wire Connector Systems for Underground Use or in Damp or Wet Locations

UL 486D

1 Scope

1.1 These requirements cover insulated wire connector systems intended for direct burial, below grade use, or similar wet locations. The wire connectors covered by these requirements are for use with copper, aluminum or copper-clad aluminum wire, or both in accordance with installations covered by the National Electrical Code, NFPA 70. These requirements cover insulating caps, covers, resins, tubing, and tapes that are part of a system, or systems, for use with specific wire connectors where the seal is made at the conductor.

1.2 These requirements also cover insulated wire connector systems intended for use with conductors of single or multiple conductor underground feeder cable (UF), golf course sprinkler cable, underground low energy cable, irrigation cable, or other cable with insulation acceptable for direct burial, below grade use, or wet locations.

1.3 These requirements apply only to insulated wire connector systems intended for use with No. 30 AWG (0.05 mm2 ) through 2000 kcmil (1012 mm2 ) conductors with currents not exceeding the ampacity of insulated conductors rated either 75?C (167?F) or 90?C (194?F) and intended for use at 600 volts or less.

1.4 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.
Edition : 5th
Number of Pages : 38
Published : 12/12/2005

History

UL 486D
Published Date: 12/12/2005
Insulated Wire Connectors for Use with Underground Connectors
UL 486D
Published Date: 02/27/1997
Insulated Wire Connectors for Use with Underground Connectors

Related products


Best-Selling Products

AFGS AFGS-87219B
Published Date: 10/23/2012
Electrical Power Systems, Aircraft
$7.2
AFGS AFGS-87241A Notice 2 - Cancellation
Published Date: 05/15/2014
Simulators, Flight (No S/S Document)
$3.6
AFGS AFGS-87249 Notice 4 - Cancellation
Published Date: 10/28/2012
Mechanical Equipment and Subsystems, Requirements for the Integrity of (S/S by MIL-STD-1798)
$3.6
AFGS AFGS-87271A Notice 1 - Validation
Published Date: 04/24/2013
Engines, Unmanned Air Vehicle, Airbreathing Gas Turbine, Expendable
$3.6