UL 486E PDF

UL 486E PDF

Name:
UL 486E PDF

Published Date:
05/07/2009

Status:
Active

Description:

Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
1 Scope

1.1 This Standard applies to equipment wiring terminals for use with all alloys of copper, aluminum, or copper-clad aluminum conductors, in accordance with the National Electrical Code, ANSI/NFPA 70, as follows:

a) equipment wiring terminals intended to hold one or more conductor(s);

b) equipment wiring terminals intended for use in appliances and equipment that comply with the requirements for such appliances and equipment;

c) ampere-rated equipment wiring terminals;

d) horsepower rated equipment wiring terminals; and

e) wire range rated equipment wiring terminals.

1.2 These requirements apply to field wired equipment wiring terminals which are an integral part of the equipment, or are intended for use in specific equipment.

1.3 This Standard is intended for equipment wiring terminals suitable for use with conductors in the size ranges as follows:

a) Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric, compressed, and compact.

b) Copper-Clad Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric.

c) Copper

1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and

2) 30 AWG (0.05 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric and compressed, and Class C concentric.

d) Compact-stranded copper conductors for 2 AWG (33.6 mm2) and larger.

e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes.

Note: For example, an equipment wiring terminal rated for 6 AWG - 250 kcmil may be additionally rated for 16 - 120 mm2.

f) Other class and strand configurations as indicated by marking.

1.4 This Standard is intended for equipment wiring terminals suitable for currents not exceeding the ampacity of insulated conductors rated 75?C or 90?C in accordance with the rating of the equipment wiring terminal, if provided.

1.5 This Standard does not apply to:

a) insulated equipment wiring terminals; and

b) wire binding screw terminals.
Edition : 4th
Number of Pages : 60
Published : 05/07/2009

History

UL 486E
Published Date: 05/07/2009
Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors
UL 486E
Published Date: 12/07/1994
Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors

Related products

UL 1602
Published Date: 01/28/2009
Gasoline-Engine-Powered, Rigid-Cutting-Member Edgers and Edger-Trimmers
$150.6

Best-Selling Products

ASA C39.1-1955
Published Date: 07/27/1955
ASA American Standard Electrical Indicating Instruments Panel, Switchboard, and Portable Instruments
$17.1
ASA C39.1-1959
Published Date: 06/30/1959
ASA American Standard Requirements for Electrical Indicating Instruments Panel, Switchboard, and Portable Instruments
$17.1
ASA S1.1-1994 (R2004)
Published Date: 03/25/2004
American National Standard Acoustical Terminology
ASA S1.1-2013 (R2024)
Published Date: 10/14/2013
American National Standard for Acoustical Terminology
$50.7
ASA S1.11-1986(R1998)
Published Date: 01/01/1986
American National Standard Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters - SAME AS ASA 65
ASA S1.11-2004 (R2009)
Published Date: 06/15/2009
American National Standard Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters (Includes Errata 2005)