UL 486E PDF

UL 486E PDF

Name:
UL 486E PDF

Published Date:
05/07/2009

Status:
Active

Description:

Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors

Publisher:
Underwriters Laboratories

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
1 Scope

1.1 This Standard applies to equipment wiring terminals for use with all alloys of copper, aluminum, or copper-clad aluminum conductors, in accordance with the National Electrical Code, ANSI/NFPA 70, as follows:

a) equipment wiring terminals intended to hold one or more conductor(s);

b) equipment wiring terminals intended for use in appliances and equipment that comply with the requirements for such appliances and equipment;

c) ampere-rated equipment wiring terminals;

d) horsepower rated equipment wiring terminals; and

e) wire range rated equipment wiring terminals.

1.2 These requirements apply to field wired equipment wiring terminals which are an integral part of the equipment, or are intended for use in specific equipment.

1.3 This Standard is intended for equipment wiring terminals suitable for use with conductors in the size ranges as follows:

a) Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric, compressed, and compact.

b) Copper-Clad Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric.

c) Copper

1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and

2) 30 AWG (0.05 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric and compressed, and Class C concentric.

d) Compact-stranded copper conductors for 2 AWG (33.6 mm2) and larger.

e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes.

Note: For example, an equipment wiring terminal rated for 6 AWG - 250 kcmil may be additionally rated for 16 - 120 mm2.

f) Other class and strand configurations as indicated by marking.

1.4 This Standard is intended for equipment wiring terminals suitable for currents not exceeding the ampacity of insulated conductors rated 75?C or 90?C in accordance with the rating of the equipment wiring terminal, if provided.

1.5 This Standard does not apply to:

a) insulated equipment wiring terminals; and

b) wire binding screw terminals.
Edition : 4th
Number of Pages : 60
Published : 05/07/2009

History

UL 486E
Published Date: 05/07/2009
Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors
UL 486E
Published Date: 12/07/1994
Equipment Wiring Terminals for Use with Aluminum and/or Copper Conductors

Related products

UL 1602
Published Date: 01/28/2009
Gasoline-Engine-Powered, Rigid-Cutting-Member Edgers and Edger-Trimmers
$150.6

Best-Selling Products

SA/SNZ HB 119:2019
Published Date: 12/20/2019
Mines and quarries electrical protection
$43.362
SA/SNZ HB 146:2018
Published Date: 05/23/2018
Management of electrical cable in mines and quarries
$30.492
SA/SNZ HB 168:2017
Published Date: 09/18/2017
Document control
$30.492
SA/SNZ HB 205:2017
Published Date: 06/30/2017
Managing health-and-safety-related risk
$23.562
SA/SNZ HB 252:2014
Published Date: 04/28/2014
Communications cabling manual - Module 3: Residential communications cabling handbook
$33.264
SA/SNZ HB 331:2020 Amd 1:2020
Published Date: 10/01/2020
Overhead line design handbook
Free Download