1 Scope

1.1 These requirements cover electric heating, water supply, and power boilers rated at 600 volts or less intended for commercial or industrial applications utilizing hot water or steam. They may also be used for commercial, industrial, or residential use space heating applications.

1.2 These boilers are intended for installation in accordance with the National Electrical Code, NFPA 70, and other applicable codes, such as the BOCA National Mechanical Code, the Standard Mechanical Code, and the Uniform Mechanical Code.

1.3 Each boiler consists of sheathed resistance-type heating elements and a vessel or tank constructed, inspected, and stamped in accordance with the applicable sections of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Each boiler is provided with one or more safety valves or safety relief valves conforming to ASME requirements with all necessary temperature or pressure regulating controls, including an integral limit control, wiring, and auxiliary equipment assembled as a unit.

1.4 These requirements do not cover water supply boilers and hot water and steam generating equipment employing constructions which are outside the scope of, or not covered by, the ASME codes, nor commercial cooking or medical and dental equipment, nor other electric heating equipment or appliances which are covered in, or as part of, separate, individual requirements. Electrode-type boilers also are not covered by these requirements.

1.5 The equipment covered by this standard shall be one of the following types of water heating boilers:

a) High Pressure - A boiler furnishing:

1) Steam at pressures in excess of 15 psi (103 kPa); or

2) Hot water at temperatures in excess of 250?F (121?C) or at pressures in excess of 160 psi (1103 kPa).

b) Low-Pressure Hot-Water and Low-Pressure Steam - A boiler furnishing:

1) Hot water at pressures not exceeding 160 psi and at temperatures not more than 250?F; or

2) A boiler furnishing steam at pressures not more than 15 psi.

c) Miniature - A boiler that does not exceed the following limits:

1) 16 inches (406 mm) inside diameter of shell; and

2) 5 cubic feet (0.14 m3) gross volume, exclusive of casing and insulation, and 100 psi (690 kPa) maximum allowable working pressure.

For the applicable ASME Code symbol, see Section 5.

1.5 revised April 7, 2009
Edition : 5th
Number of Pages : 86
Published : 04/13/2004

History

UL 834
Published Date: 04/13/2004
Heating, Water Supply, and Power Boilers - Electric
UL 834
Published Date: 01/01/1995
Heating, Water Supply, and Power Boilers - Electric

Related products

UL 696
Published Date: 02/17/2010
Electric Toys - Marking and Labeling Systems
$189.3

Best-Selling Products

HIR FTV RP 2007
Published Date: 03/01/2018
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels
$69
HIR FTV RP 2007
Published Date: 01/03/2023
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels, Recommended Practice 2007(c)
$79.5
HIR Publication 2023
Published Date: 12/31/2023
A publication providing insights into the methods used to repair small, existing, shop-fabricated steel Above-ground, Atmospheric Pressure, Vented, Tanks designed and used for Petroleum and Non- Petroleum storage
$47.7