Description:

Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies (CAN/ULC S102.2-10)

Publisher:
Underwriters Laboratories of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
This Standard is applicable to the finished surface or covering of a floor extending to a maximum depth of 65 mm. This method is also applicable to the following:
  • A Materials which cannot be tested to CAN/ULC-S102, without the use of supporting material that is not representative of the intended installation;
  • B Materials which, when tested to CAN/ULC-S102, melts or drips, or otherwise disintegrates and continues to burn on the floor of the test chamber;
  • C Materials designed for use in a relatively horizontal position with only its top surface exposed to air; or
  • D Thermoplastic materials.
Where a material cannot be readily determined to be thermoplastic or thermoset, one test is conducted in accordance with this standard and one additional test in conformance with requirements of CAN/ULC-S102, Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies.

The primary purpose of the Standard is to determine the comparative burning characteristics of the material or assembly under test by evaluating the flame spread over its surface when exposed to a test fire and thus establish a basis on which surface burning characteristics of different materials or assemblies may be compared, without specific considerations of all the end-use parameters that might affect these characteristics.

It is the intent of this Standard to register performance during the period of exposure, and not to determine suitability for use after the test exposure.
Edition : 7
Published : 07/01/2010

History

ULC 102.2
Published Date: 07/01/2010
Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies (CAN/ULC S102.2-10)

Related products

ULC 102.4
Published Date: 09/01/2017
Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways
$61.5

Best-Selling Products

CAN/ULC 554-05 (R2010)
Published Date: 10/04/2011
Standard for Water Based Agent Fire Extinguishers, Including Amendment 1
CAN/ULC 60832-09
Published Date: 04/09/2009
Insulating poles (Insulating Sticks) and Universal Tool Attachments (Fitting) for Live Working
CAN/ULC 60895-09 Draft
Published Date: 01/01/2009
Live Working - Conductive Clothing For Use at Nominal Voltage Up to 800 kV A.C. and ?600 kV D.C.
CAN/ULC 60903-09
Published Date:
Live Working - Gloves of Insulating Material
CAN/ULC 61243-3-10
Published Date: 12/01/2010
Live working -- Voltage Detectors -- Part 3: Two-Pole Low-Voltage Type
CAN/ULC 61477-05
Published Date: 01/01/2006
Live Working - Minimum Requirements for the Utilization of Tools, Devices and Equipment (CEI/IEC 61477:2001+A1:2002, IDT)