ULC 61472 PDF

ULC 61472 PDF

Name:
ULC 61472 PDF

Published Date:
06/06/2014

Status:
Active

Description:

Live Working - Minimum Approach Distances For A.C. Systems In The Voltage Range 72,5 Kv To 800 Kv - A Method Of Calculation (CAN/ULC 61472)

Publisher:
Underwriters Laboratories of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$84
Need Help?
This identical adoption of the Third Edition of IEC 61472 is an update to the Second Edition and is the First Edition of CAN/ULC-61472. Updates include clarification of the scope, review of the definitions and review of the Annexes. Other updates to the Third Edition also include modification of calculations as well as introduction of new criteria and tables.

This International Standard describes a method for calculating the minimum approach distances for live working, at maximum voltages between 72,5 kV and 800 kV. This standard addresses system overvoltages and the working air distances or tool insulation between parts and/or workers at different electric potentials.

The required withstand voltage and minimum approach distances calculated by the method described in this standard are evaluated taking into consideration the following:
  • workers are trained for, and skilled in, working in the live working zone;
  • the anticipated overvoltages do not exceed the value selected for the determination of the required minimum approach distance;
  • transient overvoltages are the determining overvoltages;
  • tool insulation has no continuous film of moisture or measurable contamination present on the surface;
  • no lightning is seen or heard within 10 km of the work site;
  • allowance is made for the effect of conducting components of tools;
  • the effect of altitude, insulators in the gap, etc, on the electric strength is taken into consideration.
    • For conditions other than the above, the evaluation of the minimum approach distances may require specific data, derived by other calculation or obtained from additional laboratory investigations on the actual situation.

Edition : 1
Note : This product is unavailable in Russia, Ukraine, Belarus
Published : 06/06/2014

History


Related products

ULC 60895
Published Date: 08/07/2012
Live Working - Conductive Clothing For Use at Nominal Voltage Up to 800 kV a.c. and +/- 600 kV d.c. (CAN/ULC 60895-09)
$49.5

Best-Selling Products

PFI ES11
Published Date: 01/01/1996
Permanent Marking on Piping Materials
PFI ES16
Published Date: 01/01/1985
Access Holes, Bosses and Plugs for Radiographic Inspection of Pipe Welds
PFI ES1
Published Date: 07/01/1995
Internal Machining & Solid Machined Backing Rings for Circumferential Butt Welds
PFI ES20
Published Date: 01/01/1997
Wall Thickness Measurement by Ultrasonic Examination
PFI ES21
Published Date: 01/01/1992
Internal Machining & Fit-Up of GTAW Root Pass Circumferential Butt Welds
PFI ES22
Published Date: 01/01/1995
Recommended Practice for Color Coding of Piping Materials