ULC 677 PDF

ULC 677 PDF

Name:
ULC 677 PDF

Published Date:
10/01/2014

Status:
Active

Description:

Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids

Publisher:
Underwriters Laboratories of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$15
Need Help?

Please note: All interim revisions for this edition available at time of your purchase will be included.



This Standard covers minimum requirements for shop fabricated, aboveground fire tested tank assemblies intended for storage of flammable and combustible liquids that have a specific gravity not greater than 1.0 and that are compatible with the material of the tank.

In addition to this Standard’s traditional safety requirements for aboveground steel tanks that primarily evaluate structural integrity and mitigate environmental hazards from loss of liquid containment under expected normal conditions; optional construction and/or performance requirements, and associated ratings intended to address more severe conditions associated with the effects of Climate Change are included in Appendix A.

Tank assemblies constructed to meet this standard are intended to withstand exposure to a 1 h hydrocarbon pool fire.

These tank assemblies are intended for stationary installation and use in accordance with the following:

  • National Fire Code of Canada, Part 4;
  • CSA B139, Installation Code for Oil Burning Equipment;
  • PN1326, Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products;
  • The Requirements of the Authority Having Jurisdiction.

Tank assemblies covered by these requirements are fabricated, inspected, and tested for leakage before shipment from the factory as completely assembled units.

These requirements do not address methods of anchoring which may be required to prevent uplift from flooding or movement due to wind or seismic forces.

These requirements do not address either the construction, or attachment means of ladders, stairs, runways, guardrails, platforms, or equipment supports.

The Standards for the primary tank to be incorporated into these fire tested tank assemblies are identified in Subsection 2, The Primary Tank. As a result of revisions to those Standards published in 2019, in addition to traditional safety requirements for tanks that primarily evaluate functional operation, structural integrity, and mitigate fire & environmental hazards from loss of liquid containment under expected normal conditions; optional construction and/or performance requirements, and associated ratings, intended to address more severe conditions associated with the effects of Climate Change are included in Appendix A.

Except for optional Climate Change Adaptation requirements in Appendix A, these requirements do not cover special evaluations for resistance to, or use after, earthquakes, floods, high wind events, or other natural disasters; or resistance to vehicle impact.

NOTE: See the Note at the beginning of Appendix A for further information on the terms “Adaptation” and “Mitigation”, as they pertain to Climate Change.


Edition : 1
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 25
Published : 10/01/2014

History

ULC 677
Published Date: 10/01/2014
Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids
$15
ULC ORD-C142.5-1992
Published Date:
Concrete Encased Steel Aboveground Tank Assemblies For Flammable and Combustible Liquids

Related products

ULC 1001
Published Date: 09/02/2011
Standard for Integrated Systems Testing of Fire Protection and Life Safety Systems
$101.1

Best-Selling Products

EUROCAE ED-100A
Published Date: 04/01/2005
INTEROPERABILITY REQUIREMENTS FOR ATS APPLICATIONS USING ARINC 622 DATA COMMUNICATIONS (FANS 1/A INTEROP STANDARD)
$56.7
EUROCAE ED-101
Published Date: 08/01/2000
MINIMUM OPERATIONAL PERFORMANCE SPECIFICATION FOR MODE S SPECIFIC SERVICE APPLICATIONS
EUROCAE ED-102A
Published Date: 12/01/2009
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102A
Published Date: 01/01/2012
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102B CHG 1
Published Date: 01/01/2022
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE - BROADCAST (ADS-B) AND TRAFFIC INFORMATION SERVICES-BROADCAST (TIS-B) - CHANGE 1
$48.6
EUROCAE ED-102B
Published Date: 12/01/2020
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE ‐ BROADCAST (ADS‐B) AND TRAFFIC INFORMATION SERVICES‐BROADCAST (TIS‐B)
$311.1