Description:

Precision Statements in UOP Methods

Publisher:
UOP LLC, A Honeywell Company

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$72
Need Help?

This method is for developing precision statements as reported in UOP methods and relative bias of the same method between different laboratories. The calculation of precision, in terms of repeatability and intermediate precision (within a laboratory), reproducibility (between laboratories) and relative bias (between laboratories) is described. Precision statements in methods having a 98 or later suffix were developed by the procedure described; methods having an 88 through 97 suffix used UOP 888-88, while methods with suffixes earlier than 88 used UOP 666-82.

The features of UOP 999 are as follows:

Minimum of 16 analyses required with emphasis on multiple concentration levels
Better identification of the components of variation and repeatability estimates
Alignment with ASTM repeatability, intermediate precision, and reproducibility definitions
Relative bias between laboratories with 95% confidence interval

UOP 999 is the minimum guideline for estimating the initial precision for new or revised methods. Once a new or revised method is in use, a reference sample, if available, should be run on a regular basis. When 16 analyses have been completed, individual and range control charts are to be used to estimate the long-term UOP repeatability and are to be maintained on an ongoing basis. The example calculations in UOP 999 are made using Minitabâ, a statistical software package. The details of the calculations are in UOP 999-97 Supplement.


File Size : 1 file , 180 KB
Number of Pages : 19
Published : 12/01/2013
Redline File Size : 2 files , 3.3 MB

History

UOP 999-13
Published Date: 12/01/2013
Precision Statements in UOP Methods
$72
UOP 999-05
Published Date: 02/01/2005
Precision Statements in UOP Methods
$86.1
UOP 999-04
Published Date: 12/17/2004
Precision Statements in UOP Methods
$86.1
UOP 999-97
Published Date: 01/01/1997
Precision Statements in UOP Methods
$86.1

Related products

UOP 741-86
Published Date: 01/01/1986
Paraffin and Naphthene Distribution by Carbon Number of Saturated Petroleum Distillates by GC
$86.1
UOP 967-12
Published Date: 06/01/2012
Automated Crush Strength of Spherical and Extruded Catalysts
$72
UOP 495-03
Published Date: 06/25/2003
Aromatics in Molex Process n-Paraffin Products by Ultraviolet Spectrophotometry
$72
UOP 714-07
Published Date: 02/28/2007
Metals in Miscellaneous Samples by ICP-OES
$72

Best-Selling Products