ASTM D4741-18 PDF

ASTM D4741-18 PDF

Name:
ASTM D4741-18 PDF

Published Date:
06/01/2018

Status:
Active

Description:

Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18
Need Help?

1.1 This test method2 covers the laboratory determination of the viscosity of oils at 150 °C and 1 × 106 s-1 and at 100 °C and 1 × 106 s-1, using high shear rate tapered-plug viscometer models BE/C or BS/C.

1.2 Newtonian calibration oils are used to adjust the working gap and for calibration of the apparatus. These calibration oils cover a range from approximately 1.4 mPa·s to 5.9 mPa·s (cP) at 150 °C and 4.2 mPa·s to 18.9 mPa·s (cP) at 100 °C. This test method should not be used for extrapolation to higher viscosities than those of the Newtonian calibration oils used for calibration of the apparatus. If it is so used, the precision statement will no longer apply. The precision has only been determined for the viscosity range 1.48 mPa·s to 5.07 mPa·s at 150 °C and from 4.9 mPa·s to 11.8 mPa·s at 100 °C for the materials listed in the precision section.

1.3 A non-Newtonian reference oil is used to check that the working conditions are correct. The exact viscosity appropriate to each batch of this oil is established by testing on a number of instruments in different laboratories. The agreed value for this reference oil may be obtained from the chairman of the Coordinating European Council (CEC) Surveillance Group for CEC L-36-90, or from the distributor.

1.4 Applicability to products other than engine oils has not been determined in preparing this test method.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard except those noted below.

1.5.1 Exception-This test method uses the SI unit millipascal-second (mPa·s) as the unit of viscosity. (1 cP = 1 mPa·s.)

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 90 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 06/01/2018
Redline File Size : 2 files , 180 KB

History

ASTM D4741-21
Published Date: 01/01/2021
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$15.6
ASTM D4741-20a
Published Date: 09/01/2020
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$20.4
ASTM D4741-20
Published Date: 06/01/2020
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$20.4
ASTM D4741-18
Published Date: 06/01/2018
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-13
Published Date: 10/01/2013
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-12
Published Date: 11/01/2012
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-06
Published Date: 05/01/2006
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-00
Published Date: 12/10/2000
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-96
Published Date: 01/01/1996
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$17.4

Related products

ASTM D5949-16(2022)
Published Date: 06/30/2022
Standard Test Method for Pour Point of Petroleum Products (Automatic Pressure Pulsing Method)
$16.2
ASTM D5772-21
Published Date: 01/01/2021
Standard Test Method for Cloud Point of Petroleum Products and Liquid Fuels (Linear Cooling Rate Method)
$15.6
ASTM D5704-24
Published Date: 05/01/2024
Standard Test Method for Evaluation of the Thermal and Oxidative Stability of Lubricating Oils Used for Manual Transmissions and Final Drive Axles
$20.7

Best-Selling Products

VDI VDE/VDI 2604
Published Date: 06/01/1971
Oberflaechen-Messverfahren; Rauheitsuntersuchung mittels Interferenzmikroskopie
$27
VDI VDI 02700 BLATT 13.1
Published Date: 05/01/2010
Ladungssicherung auf Strassenfahrzeugen - Grossraum- und Schwertransporte - Datenblatt zur Transportplanung von Grossraum- und Schwertransporten - Laengenberechnung
$9.3
VDI VDI 02700 BLATT 13.2
Published Date: 05/01/2010
Ladungssicherung auf Strassenfahrzeugen - Grossraum- und Schwertransporte - Datenblatt zur Transportplanung von Grossraum- und Schwertransporten - Winkelberechnung
$9.3
VDI VDI 03033
Published Date: 09/01/1995
Waermeuebertragungsanlagen - Musterformulare fuer ordnungsgemaesses Betreiben bzw. Dokumentieren
$16.8
VDI VDI 1000 BERICHTIGUNG
Published Date: 07/01/2020
VDI-Richtlinienarbeit - Grundsaetze und Anleitungen - Berichtigung zur Richtlinie VDI 1000:2017-02
$0.3
VDI VDI 1000
Published Date: 06/01/2010
VDI-Richtlinienarbeit - Grundsaetze und Anleitungen
$25.8