1.1 This test method2 covers the laboratory determination of the viscosity of oils at 150 °C and 1 × 106 s-1 and at 100 °C and 1 × 106 s-1, using high shear rate tapered-plug viscometer models BE/C or BS/C.

1.2 Newtonian calibration oils are used to adjust the working gap and for calibration of the apparatus. These calibration oils cover a range from approximately 1.4 mPa·s to 5.9 mPa·s (cP) at 150 °C and 4.2 mPa·s to 18.9 mPa·s (cP) at 100 °C. This test method should not be used for extrapolation to higher viscosities than those of the Newtonian calibration oils used for calibration of the apparatus. If it is so used, the precision statement will no longer apply. The precision has only been determined for the viscosity range 1.48 mPa·s to 5.07 mPa·s at 150 °C and from 4.9 mPa·s to 11.8 mPa·s at 100 °C for the materials listed in the precision section.

1.3 A non-Newtonian reference oil is used to check that the working conditions are correct. The exact viscosity appropriate to each batch of this oil is established by testing on a number of instruments in different laboratories. The agreed value for this reference oil may be obtained from the chairman of the Coordinating European Council (CEC) Surveillance Group for CEC L-36-90, or from the distributor.

1.4 Applicability to products other than engine oils has not been determined in preparing this test method.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard except those noted below.

1.5.1 Exception-This test method uses the SI unit millipascal-second (mPa·s) as the unit of viscosity. (1 cP = 1 mPa·s.)

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 96 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 6
Published : 09/01/2020
Redline File Size : 2 files , 180 KB

History

ASTM D4741-21
Published Date: 01/01/2021
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$15.6
ASTM D4741-20a
Published Date: 09/01/2020
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$20.4
ASTM D4741-20
Published Date: 06/01/2020
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$20.4
ASTM D4741-18
Published Date: 06/01/2018
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-13
Published Date: 10/01/2013
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-12
Published Date: 11/01/2012
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-06
Published Date: 05/01/2006
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-00
Published Date: 12/10/2000
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$18
ASTM D4741-96
Published Date: 01/01/1996
Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer
$17.4

Related products

ASTM D5972-23
Published Date: 03/01/2023
Standard Test Method for Freezing Point of Aviation Fuels (Automatic Phase Transition Method)
$17.1
ASTM D4860-22
Published Date: 07/01/2022
Standard Test Method for Free Water and Particulate Contamination in Middle Distillate Fuels (Clear and Bright Numerical Rating)
$18.9
ASTM D5481-21
Published Date: 12/31/2020
Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer
$15.6
ASTM D5384-14(2019)
Published Date: 05/01/2019
Standard Test Methods for Chlorine in Used Petroleum Products (Field Test Kit Method)
$12.6

Best-Selling Products

BS CISPR 12:1997
Published Date: 04/15/1999
Vehicles, motorboats and spark-ignited engine-driven devices. Radio disturbance characteristics. Limits and methods of measurement
$105.156
BS CISPR 16-1:1998
Published Date: 12/15/1998
Specification for radio disturbance and immunity measuring apparatus and methods-Radio disturbance and immunity measuring apparatus
$119.634
BS CISPR 16-1:1999
Published Date: 10/08/2003
Specification for radio disturbance and immunity measuring apparatus and methods-Radio disturbance and immunity measuring apparatus
$119.634
BS CISPR 16-2:1996
Published Date: 03/26/2003
Specification for radio disturbance and immunity measuring apparatus and methods-Methods of measurement of disturbances and immunity
$119.634
BS CISPR 16-3:2000
Published Date: 09/15/2000
Specification for radio disturbance and immunity measuring apparatus and methods-Reports and recommendations of CISPR
$119.634
CISPR 10 Amd.1 Ed. 4.0 b:1995
Published Date: 04/28/1995
Amendment 1 - Organization, rules and procedures of the CISPR
$7.5