1.1 This test method covers the on-line determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water in the range from 0.5 μg/L to 50 000 μg/L of carbon. Higher carbon levels may be determined by suitable on-line dilution. This test method utilizes ultraviolet-persulfate oxidation of organic carbon coupled with a CO2 selective membrane to recover the CO2 into deionized water. The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample using calibration data. Inorganic carbon is determined in a similar manner without the requirement for oxidation. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane. The relationship between the conductivity measurement and carbon concentration can be described by a set of chemometric equations for the chemical equilibrium of CO2, HCO3, H+, and OH, and the relationship between the ionic concentrations and the conductivity. The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances resulting in linear response of the method over the stated range of TOC. See Test Method D4519 for a discussion of the measurement of CO2 by conductivity.
1.2 This test method has the advantage of a very high sensitivity detector that allows very low detection levels on relatively small volumes of sample. Also, the use of two measurement channels allows determination of IC in the sample independently of organic carbon. Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration with minimal interferences.
1.3 This test method was used successfully with reagent water spiked with sodium carbonate and various organic compounds. This test method is effective with both deionized water samples and samples of high ionic strength. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.
1.4 This test method is applicable only to carbonaceous matter in the sample that can be introduced into the reaction zone. The inlet system generally limits the maximum size of particles that can be introduced. Filtration may also be used to remove particles, however, this may result in removal of organic carbon if the particles contain organic carbon.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

File Size : 1 file , 390 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 07/01/2024

History

ASTM D5997-15(2024)
Published Date: 07/01/2024
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18.9
ASTM D5997-96(2009)
Published Date: 10/01/2009
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18
ASTM D5997-96(2005)
Published Date: 06/01/2005
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18
ASTM D5997-96(2000)
Published Date: 01/01/2000
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$17.4

Related products

ASTM D511-14(2021)e1
Published Date: 11/01/2021
Standard Test Methods for Calcium and Magnesium In Water
$16.2
ASTM D1426-15(2021)e1
Published Date: 11/01/2021
Standard Test Methods for Ammonia Nitrogen In Water
$16.2
ASTM D6091-07(2014)
Published Date: 01/15/2014
Standard Practice for 99 %/95 % Interlaboratory Detection Estimate (IDE) for Analytical Methods with Negligible Calibration Error (Withdrawn 2023)
$22.8
ASTM D4841-88(2018)
Published Date: 10/15/2018
Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents
$15.6

Best-Selling Products

ASD-STAN 2000M CD
Published Date: 10/01/1998
International Specification for Material Management Integrated Data Processing for Military Equipment
ASD-STAN CTI/79/8089
Published Date: 01/01/1979
Tool Numbering Unification in the European Aerospace Industries
ASD-STAN DOA SET
Published Date: 01/16/2019
Design Organisation Approval standards
$277.2
ASD-STAN PREN 2000
Published Date: 10/01/2003
Aerospace Series Quality Assurance EN Aerospace Products Approval of the Quality Systems of Manufacturers
$13.2
ASD-STAN PREN 2002-001
Published Date: 03/01/2019
Aerospace series Metallic materials Test methods Part 001: Tensile testing at ambient temperature
$57.9
ASD-STAN prEN 2002-003
Published Date: 06/01/1979
Test methods for metallic materials - Part 3 : Load calibration of tensile testing machines
$5.232