ASTM D5997-96(2009) PDF

ASTM D5997-96(2009) PDF

Name:
ASTM D5997-96(2009) PDF

Published Date:
10/01/2009

Status:
Active

Description:

Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18
Need Help?

1.1 This test method covers the on-line determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water in the range from 0.5 μg/L to 50 000 μg/L of carbon. Higher carbon levels may be determined by suitable on-line dilution. This test method utilizes ultraviolet-persulfate oxidation of organic carbon coupled with a CO2 selective membrane to recover the CO2 into deionized water. The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample using calibration data. Inorganic carbon is determined in a similar manner without the requirement for oxidation. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane. The relationship between the conductivity measurement and carbon concentration can be described by a set of chemometric equations for the chemical equilibrium of CO2, HCO3 , H +, and OH , and the relationship between the ionic concentrations and the conductivity. The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances resulting in linear response of the method over the stated range of TOC. See Test Method D4519 for a discussion of the measurement of CO2 by conductivity.

1.2 This test method has the advantage of a very high sensitivity detector that allows very low detection levels on relatively small volumes of sample. Also, the use of two measurement channels allows determination of IC in the sample independently of organic carbon. Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration with minimal interferences.

1.3 This test method was used successfully with reagent water spiked with sodium carbonate and various organic compounds. This test method is effective with both deionized water samples and samples of high ionic strength. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.4 This test method is applicable only to carbonaceous matter in the sample that can be introduced into the reaction zone. The inlet system generally limits the maximum size of particles that can be introduced. Filtration may also be used to remove particles, however, this may result in removal of organic carbon if the particles contain organic carbon.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 120 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 7
Published : 10/01/2009

History

ASTM D5997-15(2024)
Published Date: 07/01/2024
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18.9
ASTM D5997-96(2009)
Published Date: 10/01/2009
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18
ASTM D5997-96(2005)
Published Date: 06/01/2005
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$18
ASTM D5997-96(2000)
Published Date: 01/01/2000
Standard Test Method for On-Line Monitoring of Total Carbon, Inorganic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection
$17.4

Related products

ASTM D1125-23
Published Date: 04/01/2023
Standard Test Methods for Electrical Conductivity and Resistivity of Water
$17.1
ASTM D5612-94(2018)
Published Date: 10/15/2018
Standard Guide for Quality Planning and Field Implementation of a Water Quality Measurement Program
$14.4
ASTM D5613-94(2014)
Published Date: 01/01/2014
Standard Test Method for Open-Channel Measurement of Time of Travel Using Dye Tracers (Withdrawn 2023)
$22.8
ASTM D516-22
Published Date: 12/01/2022
Standard Test Method for Sulfate Ion in Water
$17.1

Best-Selling Products

SCTE 01 1996R2001
Published Date: 01/01/1996
"F" Port (Female Outdoor) Physical Dimensions (formerly IPS SP 400)
$9
SCTE 01 2006
Published Date: 01/01/2006
"F" Port (Female Outdoor) Physical Dimensions (formerly IPS SP 400)
$7.5
SCTE 01 2021
Published Date: 2021
Specification for "F" Port, Female, Outdoor
$7.5
SCTE 02 2006
Published Date: 01/01/2006
Specification for "F" Port, Female, Indoor
$7.5
SCTE 02 2021
Published Date: 2021
Specification for "F" Port, Female, Indoor
$7.5
SCTE 03 2003
Published Date: 01/01/2003
Test Method for Coaxial Cable Structural Return Loss (formerly IPS TP 007)
$7.5