ASTM D6096-21 PDF

ASTM D6096-21 PDF

Name:
ASTM D6096-21 PDF

Published Date:
01/01/2021

Status:
Active

Description:

Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 oC Operation

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-d6096-21_2210517

Choose Document Language:
13.80 €
Need Help?

1.1''This specification covers a thermoplastic insulation of poly (vinyl chloride) or the copolymer of vinyl chloride and vinyl acetate. This insulation is recommended for use at conductor temperatures not in excess of 90 ''C.

1.2''Depending on the thickness of the insulation, the maximum voltage used, and whether the location is wet or dry, this insulation is acceptable for use in 300 V (dry) and 600 V (wet or dry) power and control circuits.

1.3''This insulation has potential low-temperature installation limitations. Consult the manufacturer for specific recommendations for installation.

1.4''In many instances, the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable.

1.5''The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5.1''In some cases (including the title), temperatures are described in degrees Celsius only.

1.6''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 69 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 3
Published : 01/01/2021
Redline File Size : 2 files , 140 KB

History

ASTM D6096-21
Published Date: 01/01/2021
Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 oC Operation
13.80 €
ASTM D6096-11
Published Date: 08/01/2011
Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 degreesC Operation
15.60 €
ASTM D6096-07
Published Date: 10/01/2007
Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 degrees ;C Operation
15.60 €
ASTM D6096-02
Published Date: 09/10/2002
Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 degrees C Operation
15.60 €
ASTM D6096-97
Published Date: 03/10/1997
Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90 degrees C Operation
16.20 €

Related products

ASTM D4247-99(2004)
Published Date: 04/10/1999
Standard Specification for General-Purpose, Black Heavy-Duty, and Black Extra-Heavy-Duty Crosslinked Polychloroprene Jackets for Wire and Cable (Withdrawn 2006)
15.60 €
ASTM D4880-18
Published Date: 11/01/2018
Standard Test Method for Salt Water Proofness of Insulating Varnishes Over Enamelled Magnet Wire
12.60 €
ASTM D2656-20
Published Date: 10/01/2020
Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V
13.80 €

Best-Selling Products

HIR FTV RP 2007
Published Date: 03/01/2018
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels
69.00 €
HIR FTV RP 2007
Published Date: 01/03/2023
In-service Inspection of Aboveground Atmospheric Fiberglass Reinforced Plastic Tanks and Vessels, Recommended Practice 2007(c)
79.50 €
HIR Publication 2023
Published Date: 12/31/2023
A publication providing insights into the methods used to repair small, existing, shop-fabricated steel Above-ground, Atmospheric Pressure, Vented, Tanks designed and used for Petroleum and Non- Petroleum storage
47.70 €