ASTM D7094-17a PDF

ASTM D7094-17a PDF

Name:
ASTM D7094-17a PDF

Published Date:
12/01/2017

Status:
Active

Description:

Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$22.5
Need Help?

1.1 This test method covers the determination of the flash point of fuels including diesel/biodiesel blends, lube oils, solvents, and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5 °C per minute.

1.1.1 Apparatus requiring a specimen size of 1 mL, cup size of 4 mL, and a heating rate of 5.5 °C per minute must be run according to Test Method D6450.

1.2 This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method.

Note 1: Flash point values are not a constant physical chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can, therefore, only be defined in terms of a standard test method and no general valid correlation can be guaranteed between results obtained by different test methods or where different test apparatus is specified.

1.3 This test method utilizes a closed but unsealed cup with air injected into the test chamber.

1.4 This test method is suitable for testing samples with a flash point from 35 °C to 225 °C.

Note 2: Flash point determinations below 35 °C and above 225 °C may be performed; however, the precision has not been determined below and above these temperatures.

1.5 If the user's specification requires a defined flash point method other than this method, neither this method nor any other test method should be substituted for the prescribed test method without obtaining comparative data and an agreement from the specifier.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Temperatures are in degrees Celsius, pressure in kilo-Pascals.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.2, 8.5, and 10.1.2.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 210 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 10
Published : 12/01/2017
Redline File Size : 2 files , 450 KB

History

ASTM D7094-23
Published Date: 12/01/2023
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$18.9
ASTM D7094-17a
Published Date: 12/01/2017
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$22.5
ASTM D7094-17
Published Date: 05/01/2017
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$17.4
ASTM D7094-12e1
Published Date: 12/01/2012
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$18
ASTM D7094-12
Published Date: 12/01/2012
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$18
ASTM D7094-04(2009)
Published Date: 12/01/2009
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$18
ASTM D7094-04
Published Date: 11/01/2004
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
$17.4

Related products

ASTM D5949-16(2022)
Published Date: 06/30/2022
Standard Test Method for Pour Point of Petroleum Products (Automatic Pressure Pulsing Method)
$16.2
ASTM D6160-21
Published Date: 12/01/2021
Standard Test Method for Determination of Polychlorinated Biphenyls (PCBs) in Waste Materials by Gas Chromatography
$18
ASTM D6022-19
Published Date: 12/01/2019
Standard Practice for Calculation of Permanent Shear Stability Index
$13.2
ASTM D5760-19
Published Date: 05/01/2019
Standard Specification for Performance of Manual Transmission Gear Lubricants
$12.6

Best-Selling Products

NETA ATS-2009
Published Date: 02/19/2009
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2009 Edition
$247.5
NETA ATS-2013
Published Date: 2013
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2013 Edition
$82.5
NETA ATS-2017
Published Date: 2017
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2017 Edition (Errata Included)
$87
NETA ATS-2021
Published Date: 09/18/2020
Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2021 Edition
$87
NETA ECS-2020
Published Date: 2020
Standard for Electrical Commissioning Specifications for Electrical Power Equipment and Systems, 2020 Edition
$57
NETA ECS-2024
Published Date: 2024
Standard for Electrical Commissioning Specifications for Electrical Power Equipment & Systems, 2024 Edition
$62.7