ASTM D7094-23 PDF

ASTM D7094-23 PDF

Name:
ASTM D7094-23 PDF

Published Date:
12/01/2023

Status:
Active

Description:

Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-d7094-23_2579443

Choose Document Language:
18.90 €
Need Help?
1.1 This test method covers the determination of the flash point of fuels including diesel/biodiesel blends, lube oils, solvents, and other liquids by a continuously closed cup tester utilizing a specimen size of 2 mL, cup size of 7 mL, with a heating rate of 2.5 °C per minute. 1.1.1 Apparatus requiring a specimen size of 1 mL, cup size of 4 mL, and a heating rate of 5.5 °C per minute must be run according to Test Method D6450. 1.2 This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available and every flash point test method, including this one, is an empirical method. Note 1: Flash point values are not a constant physical chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can, therefore, only be defined in terms of a standard test method and no general valid correlation can be guaranteed between results obtained by different test methods or where different test apparatus is specified. 1.3 This test method utilizes a closed but unsealed cup with air injected into the test chamber. 1.4 The precision of this test method is applicable for testing samples with a flash point from 22.5 °C to 235.5 °C. Determinations below and above this range may be performed; however, the precision has not been established. 1.5 If the user''s specification requires a defined flash point method other than this method, neither this method nor any other test method should be substituted for the prescribed test method without obtaining comparative data and an agreement from the specifier. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Temperatures are in degrees Celsius, pressure in kilo-Pascals. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.2 and 8.5. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
File Size : 1 file , 450 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 10
Published : 12/01/2023
Redline File Size : 2 files , 710 KB

History

ASTM D7094-23
Published Date: 12/01/2023
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
18.90 €
ASTM D7094-17a
Published Date: 12/01/2017
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
22.50 €
ASTM D7094-17
Published Date: 05/01/2017
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
17.40 €
ASTM D7094-12e1
Published Date: 12/01/2012
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
18.00 €
ASTM D7094-12
Published Date: 12/01/2012
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
18.00 €
ASTM D7094-04(2009)
Published Date: 12/01/2009
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
18.00 €
ASTM D7094-04
Published Date: 11/01/2004
Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
17.40 €

Related products

ASTM D6074-15(2022)
Published Date: 10/01/2022
Standard Guide for Characterizing Hydrocarbon Lubricant Base Oils
17.10 €
ASTM D6447-09(2021)
Published Date: 12/31/2020
Standard Test Method for Hydroperoxide Number of Aviation Turbine Fuels by Voltammetric Analysis
15.60 €
ASTM D6709-24
Published Date: 03/01/2024
Standard Test Method for Evaluation of Automotive Engine Oils in the Sequence VIII Spark-Ignition Engine (CLR Oil Test Engine)
27.00 €

Best-Selling Products

IEEE/ISO/IEC 10038-1993
Published Date: 07/08/1993
ISO/IEC/IEEE International Standard for Information technology-Telecommunications and information exchange between systems - Local area networks - Media access control (MAC) bridges
86.70 €
IEEE/ISO/IEC 11073-10201-2004
Published Date: 12/15/2004
ISO/IEEE International Standard for Health Informatics - Point-of-care medical device communication - Part 10201: Domain information model
82.80 €
IEEE/ISO/IEC 11073-10201-2020
Published Date: 05/25/2020
ISO/IEC/IEEE International Standard - Health informatics--Device interoperability--Part 10201:Point-of-care medical device communication--Domain information model
48.00 €
IEEE/ISO/IEC 11073-20701-2020
Published Date: 03/30/2020
ISO/IEC/IEEE International Standard for Health informatics--Device interoperability--Part 20701:Point-of-care medical device communication--Service oriented medical device exchange architecture and protocol binding
20.40 €
IEEE/ISO/IEC 12207-2008
Published Date: 01/31/2008
ISO/IEC/IEEE International Standard - Systems and software engineering -- Software life cycle processes
103.20 €
IEEE/ISO/IEC 12207-2
Published Date:
ISO/IEC/IEEE Draft International Standard - Systems and Software Engineering -- Software Life Cycle Processes -- Part 2: Relation and Mapping Between ISO/IEC/IEEE 12207-1:2017 and ISO/IEC/IEEE 12207:2008