Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
astm-d7600-09e2_1858289

Choose Document Language:
18.00 €
Need Help?

1.1 This procedure covers the determination of aldicarb, carbofuran, oxamyl and methomyl (referred to collectively as carbamates in this test method) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). These analytes are qualitatively and quantitatively determined by this method. This method adheres to multiple reaction monitoring (MRM) mass spectrometry.

1.2 This test method has been developed by US EPA Region 5 Chicago Regional Laboratory (CRL).

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 The Detection Verification Level (DVL) and Reporting Range for the carbamates are listed in Table 1.

TABLE 1 Detection Verification Level and Reporting Range

Analyte

DVL (ng/L)†

Reporting Range (μg/L)

Aldicarb

100

1-100

Carbofuran

100

1-100

Oxamyl

100

1-100

Methomyl

100

1-100

† Measurement editorially corrected.


1.4.1 The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratios of the primary single reaction monitoring (SRM) transitions and Fig. 2 displays the confirmatory SRM transitions at the DVLs for the carbamates.


FIG. 1 Example Primary SRM Chromatograms Signal/Noise Ratios
FIG. 2 Example Confirmatory SRM Chromatograms Signal/Noise Ratios

1.4.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 2 for the carbamates.

TABLE 2 Concentrations of Calibration Standards (PPB)

Analyte/Surrogate

LV 1

LV 2

LV 3

LV 4

LV 5

LV 6

Aldicarb

1

5

10

25

50

100

Carbofuran

1

5

10

25

50

100

Oxamyl

1

5

10

25

50

100

Methomyl

1

5

10

25

50

100

BDMC (Surrogate)

2

10

20

50

100

200


1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 480 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 10
Published : 12/01/2009

History

ASTM D7600-16(2024)
Published Date: 04/01/2024
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
18.90 €
ASTM D7600-16(2017)
Published Date: 06/15/2017
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
22.50 €
ASTM D7600-09e3
Published Date: 12/01/2009
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
18.00 €
ASTM D7600-09e2
Published Date: 12/01/2009
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
18.00 €
ASTM D7600-09e1
Published Date: 12/01/2009
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
18.00 €
ASTM D7600-09
Published Date: 12/01/2009
Standard Test Method for Determination of Aldicarb, Carbofuran, Oxamyl and Methomyl by Liquid Chromatography/Tandem Mass Spectrometry
17.40 €

Related products

ASTM D7066-04(2024)
Published Date: 04/01/2024
Standard Test Method for dimer/trimer of chlorotrifluoroethylene (S-316) Recoverable Oil and Grease and Nonpolar Material by Infrared Determination
18.90 €
ASTM D4195-23
Published Date: 04/01/2023
Standard Guide for Water Analysis for Reverse Osmosis and Nanofiltration Application
15.00 €
ASTM D3921-96(2011)
Published Date: 05/01/2011
Standard Test Method for Oil and Grease and Petroleum Hydrocarbons in Water (Withdrawn 2013)
18.00 €
ASTM D7065-17(2024)
Published Date: 04/01/2024
Standard Test Method for Determination of Nonylphenol, Bisphenol A, <emph type="bdit" >p-tert</emph>-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Gas Chromatography Mass Spectrometry
20.70 €

Best-Selling Products

NIST HDBK 150
Published Date: 07/01/2016
National Voluntary Laboratory Accreditation Program Procedures and General Requirements
14.10 €
NIST HDBK 150
Published Date: 02/01/2006
National Voluntary Laboratory Accreditation Program Procedures and General Requirements
16.20 €
NIST HDBK 44
Published Date: 01/01/2018
Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices
36.00 €
NIST NISTIR 6969
Published Date: 09/01/2014
Selected Laboratory and Measurement Practices and Procedures to Support Basic Mass Calibrations
21.60 €
NIST NISTIR 7628
Published Date: 09/01/2014
Guidelines for Smart Grid Cybersecurity Volume 1 - Smart Grid Cybersecurity Strategy, Architecture, and High-Level Requirements
39.60 €