1.1 This practice provides a methodology to use an in-situ procedure for the evaluation of delayed contact hypersensitivity reactions.

1.2 This practice is intended to provide an alternative to the use of guinea pigs for evaluation of the ability of a device material to stimulate delayed contact hypersensitivity reactions. This alternative is particularly applicable for materials used in devices that contact only intact skin. However, the guinea pig maximization test is still the recommended method when assessing the delayed hypersensitivity response to metals or when testing substances that do not penetrate the skin but are used in devices that contact deep tissues or breached surfaces. This practice may be used for testing metals, with the exception of nickel-containing metals, unless the unique physicochemical properties of the materials may interfere with the ability of LLNA to detect sensitizing substances.

1.3 This practice consists of a protocol for assessing an increase in lymphocyte proliferation within the nodes draining the site of administration on the ears of mice.

1.4 The LLNA has been validated only for low-molecular-weight chemicals that can penetrate the skin. The absorbed chemical or metabolite must bind to macromolecules, such as proteins, to form immunogenic conjugates.

1.5 This practice is one of several developed for the assessment of the biocompatibility of materials. Practice F748 may provide guidance for the selection of appropriate methods for testing materials for a specific application.

1.6 Identification of a supplier of materials or reagents is for the convenience of the user and does not imply a single source. Appropriate materials and reagents may be obtained from many commercial supply houses.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 81 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 06/01/2013
Redline File Size : 2 files , 160 KB

History

ASTM F2148-18
Published Date: 12/01/2018
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$14.4
ASTM F2148-13
Published Date: 06/01/2013
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-07(2012)
Published Date: 10/01/2012
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-07e1
Published Date: 02/01/2007
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-01
Published Date: 10/10/2001
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4

Related products

ASTM F2118-14(2020)
Published Date: 09/01/2020
Standard Test Method for Constant Amplitude of Force Controlled Fatigue Testing of Acrylic Bone Cement Materials
$16.8
ASTM F1820-22
Published Date: 03/15/2022
Standard Test Method for Determining the Forces for Disassembly of Modular Acetabular Devices
$16.2
ASTM F2182-19e2
Published Date: 09/15/2019
Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging
$16.8
ASTM F2502-24
Published Date: 09/01/2024
Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants
$20.7

Best-Selling Products

SN-CEN/CLC/TR 14060:2014
Published Date: 12/03/2014
Medical device traceability enabled by unique device identification (UDI)
SN-CEN/CLC/TR 16103:2010
Published Date: 05/12/2010
Energy management and energy efficiency — Glossary of terms
SN-CEN/CLC/TR 16567:2013
Published Date: 09/18/2013
Energy Efficiency Obligation Schemes in Europe — Overview and analysis of main features and possibilities for harmonisation
SN-CEN/CLC/TR 16832:2015
Published Date: 04/24/2015
Selection, use, care and maintenance of personal protective equipment for preventing electrostatic risks in hazardous areas (explosion risks)
SN-CEN/CLC/TR 17602-70-23:2021
Published Date: 11/24/2021
Space product assurance — Materials, mechanical parts and processes obsolescence management handbook
SN-CEN/CLC/TR 17602-80-01:2021
Published Date: 11/24/2021
Space product assurance — Reuse of existing software