ASTM F2148-18 PDF

ASTM F2148-18 PDF

Name:
ASTM F2148-18 PDF

Published Date:
12/01/2018

Status:
Active

Description:

Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$14.4
Need Help?

1.1 This practice provides a methodology to use a combination of in vivio and in situ procedures for the evaluation of delayed contact hypersensitivity reactions.

1.2 This practice is intended to provide an alternative to the use of guinea pigs for evaluation of the ability of a device material to stimulate delayed contact hypersensitivity reactions. This alternative is particularly applicable for materials used in devices that contact only intact skin. However, the guinea pig maximization test is still the recommended method when assessing the delayed hypersensitivity response to metals or when testing substances that do not penetrate the skin but are used in devices that contact deep tissues or breached surfaces. This practice may be used for testing metals, with the exception of nickel-containing metals, unless the unique physicochemical properties of the materials may interfere with the ability of LLNA to detect sensitizing substances.

1.3 This practice consists of a protocol for assessing an increase in lymphocyte proliferation in the lymph nodes draining the site of test article administration on the ears of mice.

1.4 The LLNA has been validated only for low-molecular-weight chemicals that can penetrate the skin. The absorbed chemical or metabolite must bind to macromolecules, such as proteins, to form immunogenic conjugates.

1.5 This practice is one of several developed for the assessment of the biocompatibility of materials. Practice F748 may provide guidance for the selection of appropriate methods for testing materials for a specific application.

1.6 Identification of a supplier of materials or reagents is for the convenience of the user and does not imply a single source. Appropriate materials and reagents may be obtained from many commercial supply houses.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


File Size : 1 file , 83 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 5
Published : 12/01/2018
Redline File Size : 2 files , 160 KB

History

ASTM F2148-18
Published Date: 12/01/2018
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$14.4
ASTM F2148-13
Published Date: 06/01/2013
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-07(2012)
Published Date: 10/01/2012
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-07e1
Published Date: 02/01/2007
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4
ASTM F2148-01
Published Date: 10/10/2001
Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
$17.4

Related products

ASTM F1748-96
Published Date: 01/01/1996
Test Method for External Fixator Subassemblies (Withdrawn 2000)
$15
ASTM F1264-24
Published Date: 08/15/2024
Standard Specification and Test Methods for Intramedullary Fixation Devices
$20.7
ASTM F2025-06(2018)
Published Date: 04/01/2018
Standard Practice for Gravimetric Measurement of Polymeric Components for Wear Assessment
$14.4
ASTM F1658-95
Published Date: 11/10/1995
Test Method for Shear Testing of Calcium Phosphate Coatings (Withdrawn 2000)
$15

Best-Selling Products

Discovering the Essential Universe
Published Date: 12/01/2000
$10.5
Environmental Chemistry
Published Date: 10/01/1999
$37.2
The Basic Practice of Statistics
Published Date: 07/01/1999
$28.8