AWWA ACE54330 PDF

AWWA ACE54330 PDF

Name:
AWWA ACE54330 PDF

Published Date:
06/01/2001

Status:
Active

Description:

Conversion to Sodium Hypochlorite: The Good, the Bad, and the Ugly

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Northern Kentucky Water District (District) of Fort Thomas, Kentucky owns and operates two surface water treatment plants of 44 million gallons per day (mgd) and 10 mgd capacity that draw from the Ohio and Licking Rivers, respectively. The District uses free chlorine for disinfection and adds chlorine at both treatment plants and at four booster pumping stations in the distribution system. In 1998, the District converted the smaller treatment plant and the four booster chlorine stations from chlorine gas to sodium hypochlorite. In 2000, the District converted the large treatment plant from gas to sodium hypochlorite.The District has been pleased with the conversion because it has increased safety for both the staff members and the public. There have been several difficulties in the conversion including vapor locking in the feed systems and instability of the sodium hypochlorite solution. The District has several suggestions for utilities that wish to make this conversion including the installation of pH meters to indicate solution stability and establishment of a regular maintenance program for scale removal and leak repair.
Edition : Vol. - No.
File Size : 1 file , 220 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 6
Published : 06/01/2001

History


Related products

AWWA ACE54255
Published Date: 06/01/2001
Integrating Coagulation Pretreatment With Membrane Filtration: Mechanisms for Fouling by Dissolved Organic Matter
$7.2
AWWA ACE54437
Published Date: 06/01/2001
Elements of a Brackish Water Resources Master Plan for El Paso, Texas
$7.2
AWWA ACE54275
Published Date: 06/01/2001
Modeling Riverbank Filtration Systems to Attenuate Shock Loads in Rivers
$7.2
AWWA ACE54282
Published Date: 06/01/2001
Enhanced Corrosion of Iron for Arsenic Removal From Drinking Water
$7.2

Best-Selling Products

PIP ARC01015
Published Date: 06/01/2002
Architectural and Building Utilities Design Criteria
$55.5
PIP ARC01015
Published Date: 02/01/2009
Architectural and Building Utilities Design Criteria [Complete Revision]
$57
PIP ARC01015
Published Date: 12/01/2014
Architectural and Building Utilities Design Criteria [Complete Revision]
$55.5
PIP ARC01016-EEDS
Published Date: 02/01/2009
Electronic Entry Data Sheet for Building
$15
PIP ARC01016-EEDS
Published Date: 12/01/2014
Electronic Entry Data Sheet for Building [Complete Revision]
$15
PIP ARC01016
Published Date: 08/01/2002
Building Data Sheet
$15