AWWA ACE54425 PDF

AWWA ACE54425 PDF

Name:
AWWA ACE54425 PDF

Published Date:
06/01/2001

Status:
Active

Description:

New Analytical Tools for Distribution System Surveillance

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The presence of coliforms in distribution system samples is one of the major concerns for utilities. Progress has to be made in the area of coliform analysis to allow utilities to improve their control of distributed water quality. The Direct Viable Count-Fluorescent in situ Hybridization (DVC-FISH) method and an enzymatic CHEMSCAN-based method are two new analytical methods. After evaluation, they proved to be more sensitive, specific and rapid than the standardized culture method, and to be well adapted to monitoring distribution system contamination. The study presented here covers a survey in the suburbs of the Paris, France network. Parameters under study were E.coli counts using the DVC-FISH technique, the CHEMSCAN technique and the standardized culture method. The results demonstrate that the water quality was excellent during the study, with very little non-compliance and no confirmed coliform positive sample in the official sanitary control (over 100 samples/week). In spite of these satisfactory results for compliance, the use of the DVC-FISH technique revealed that E.coli were nevertheless present in the distribution system, although not detectable with agar cultures. When comparing E.coli counts obtained with the DVC-FISH and the CHEMSCAN technique, it appears that the DVC-FISH technique leads to a higher number of positive results than the CHEMSCAN technique. The spatial distribution of positive samples appears to be uneven, with 4 points which were never positive, and 2 which were positive in 47% of cases. The use of this new analytical technique proved to be very promising, and to give an appreciably better insight into water quality. One of the major problems for utilities is the significance of coliform positive samples, and these new techniques obviously are an alternative to current bacteria counts. There is therefore a good potential for application in drinking water monitoring, allowing utilities to anticipate non-compliance and take protective measures in time. Includes 6 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 290 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 9
Published : 06/01/2001

History


Related products

AWWA ACE54334
Published Date: 06/01/2001
Practical Application of Online Instruments
$7.2
AWWA ACE54448
Published Date: 06/01/2001
Kansas Water Plan Programs for Reducing Unaccounted for Water
$7.2
AWWA ACE54436
Published Date: 06/01/2001
Electrodialysis Desalination of Surface and Waste Waters
$7.2
AWWA ACE54342
Published Date: 06/01/2001
Effects of Initial Microbial Density on Disinfection Efficiency
$7.2

Best-Selling Products

AI/ASPHALT AI MS-16
Published Date: 03/01/1983
ASPHALT IN PAVEMENT PRESERVATION & MAINTENANCE
AI/ASPHALT AI MS-17
Published Date: 01/01/1969
ASPHALT OVERLAYS FOR HIGHWAY AND STREET REHABILITATION
AI/ASPHALT AI MS-17
Published Date: 06/01/1983
ASPHALT OVERLAYS FOR HIGHWAY AND STREET REHABILITATION
AI/ASPHALT AI MS-17
Published Date: 01/01/2000
ASPHALT OVERLAYS FOR HIGHWAY AND STREET REHABILITATION
AI/ASPHALT AI MS-1
Published Date: 01/01/2008
THICKNESS DESIGN ASPHALT PAVEMENTS FOR HIGHWAYS & STREETS
$19.5
AI/ASPHALT AI MS-22
Published Date: 01/01/1983
CONSTRUCTION OF HOT MIX ASPHALT PAVEMENTS
$8.7