AWWA ACE56320 PDF

AWWA ACE56320 PDF

Name:
AWWA ACE56320 PDF

Published Date:
06/16/2002

Status:
Active

Description:

Assessment of Existing Disinfection Practices for Inactivation of Emerging Pathogens

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
The overall objective of this project was to evaluate the efficacy of chemical and photochemical disinfectants in inactivating selected emerging waterborne pathogens. The specific objectives of the project were to: assess microbial inactivation kinetics of selected emerging pathogens; compare the inactivation rates of the selected emerging pathogens to those pathogens that are of considerable concern today (Giardia and Cryptosporidium); determine the impact of selected water quality parameters on inactivation of the selected emerging pathogens; develop and assess selected CT criteria for the emerging pathogens; and, determine whether existing disinfection practices provide adequate treatment for the emerging pathogens. The following emerging pathogens were studied: adenovirus 40; feline calicivirus (as a surrogate for human caliciviruses); mycobacterium fortuitum; legionella pneumophila; and, microsporidia (Encephalitozoon intestinalis). Experiments were conducted using 1,000-mL glass beakers as reactors. The control reactors contained test water and microorganisms, but no disinfectant. The other reactors contained test water, microorganisms and disinfectant (added at t=0). Separate identical reactors were used to collect the disinfectant residual samples and the microbial inactivation samples. The reactors were set up in a recirculating, temperature-controlled water bath. Prior to each experiment the temperature was set at the target temperature for that particular experiment, and was checked using a thermometer with an error of 0.5C. The control samples for bacteria density were taken at the beginning and the end of each experiment. Disinfectant residual and microbial inactivation samples were collected throughout the experiment. The disinfectant residual samples were analyzed immediately. Upon collection, the microbial inactivation samples were mixed with 10 percent sodium thiosulfate solution to remove residual disinfectant. Includes 14 references, tables, figures.
Edition : Vol. - No.
File Size : 1 file , 380 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 13
Published : 06/16/2002

History


Related products

AWWA ACE56149
Published Date: 06/16/2002
Bridging the Gap Between Consultant and Partner: Leveraging the Public-Private Partnership
$7.2
AWWA ACE56176
Published Date: 06/16/2002
There's Nitrates in the Well: What Are Your Options?
$7.2
AWWA ACE56216
Published Date: 06/16/2002
Full-Scale Evaluation of UV Technology for Compliance With New Regulations
$7.2
AWWA ACE56272
Published Date: 06/16/2002
e-OPS System Provides Data Management and Improved Operations
$7.2

Best-Selling Products